1998
DOI: 10.1016/s0883-5403(98)80003-x
|View full text |Cite
|
Sign up to set email alerts
|

Effects of acetabular abduction on cup wear rates in total hip arthroplasty

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

3
69
1
9

Year Published

2002
2002
2018
2018

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 137 publications
(82 citation statements)
references
References 10 publications
3
69
1
9
Order By: Relevance
“…Correct acetabular orientation also reduces contact stresses [22]. However, the literature to date has been equivocal on the effect of offset and acetabular orientation on linear and volumetric wear [4,5,10,12,23].…”
Section: Introductionmentioning
confidence: 99%
“…Correct acetabular orientation also reduces contact stresses [22]. However, the literature to date has been equivocal on the effect of offset and acetabular orientation on linear and volumetric wear [4,5,10,12,23].…”
Section: Introductionmentioning
confidence: 99%
“…Although authors disagree about recommendations for where the acetabular component should be positioned (for example, some would describe ideal acetabular inclination as 45°± 10°, while others would say 40°± 10°), it is agreed suboptimal acetabular positioning can lead to construct instability and detrimental wear characteristics [4,11,19,23]. Although more horizontal component positioning reportedly reduces the rate of dislocation, there appear to be higher contact stresses when the acetabulum is positioned this way [21,22], which may lead to increased PE wear [10,21,22,30]. A potential alternative to conventional metalon-PE bearing surfaces is alumina-ceramic-on-ceramic.…”
Section: Introductionmentioning
confidence: 99%
“…So ist eine Pfannenfehlpositionierung die häufigste Ursache von postoperativen Luxationen der Hüfttotalen-doprothesen, für die eine Inzidenz von 1% bis nahezu 10% beschrieben wird [3]. Des weiteren verringert eine ungünstige Pfannenposition den Bewegungsumfang des Kunstgelenkes und kann Ursache für einen vermehrten Abrieb der Gleitpaarungen sein [2,11]. Nur die Kombination von bewährten Endoprothesenmodellen und einer exakten Implantationstechnik gewährleistet gute Langzeitergebnisse mit einer 10 Jahres-Überlebensrate von mehr als 98% [14].…”
Section: Diskussionunclassified
“…Eine ungenaue Pfannenimplantation außerhalb dieser "safe zone" schränkt den möglichen Bewegungsumfang (range of motion) des künstlichen Hüft-gelenkes ein, kann durch unphysiologische Belastungen zu einem erhöhten Abrieb der Gleitflächen und zu einer vorzeitigen aseptischen Prothesenlockerung führen sowie eine erhöhte Luxationsgefahr bedingen [2,11,18].…”
Section: Introductionunclassified
See 1 more Smart Citation