Effects of Ag and Cu ions on the microbial corrosion of 316L stainless steel in the presence of Desulfovibrio sp.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
12
0
1

Year Published

2017
2017
2025
2025

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 36 publications
(14 citation statements)
references
References 33 publications
1
12
0
1
Order By: Relevance
“…As can be seen, the obvious localized corrosion was found on the 304SS coupon in the SRB solution (as indicated by red arrows in the Figure 6b). This can be attributed to the MIC effect, leading to the deterioration of passive film by sulfide produced by SRB [42] after being immersed in the SRB solution. These results provide considerable support for our potentiodynamic polarization curve results that the lower current density of the anodic branch and poor passivity were found on the 304SS coupon immersed in the SRB solution.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…As can be seen, the obvious localized corrosion was found on the 304SS coupon in the SRB solution (as indicated by red arrows in the Figure 6b). This can be attributed to the MIC effect, leading to the deterioration of passive film by sulfide produced by SRB [42] after being immersed in the SRB solution. These results provide considerable support for our potentiodynamic polarization curve results that the lower current density of the anodic branch and poor passivity were found on the 304SS coupon immersed in the SRB solution.…”
Section: Resultsmentioning
confidence: 99%
“…Potentiodynamic polarization curves were deduced using a Gamry Reference 600 potentiostat (Warminster, PA, USA) to evaluate corrosion performance [5,6,8,42,43,44]. A standard three-electrode system comprising a graphite counter electrode and saturated calomel electrode (SCE) as a reference electrode was used in all electrochemical tests.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Faz-frekans eğrilerine göre 0.5 sa (0. ay) ait olan eğrinin faz açısının yüksek değerde ve orta frekans bölgesinde bir lupa sahip olduğu, diğer aylarda ise lupların yüksek frekans bölgesine doğru kaydığı tespit edilmiştir. Bu durum biyofilmin zamanla olgunlaştığına ve dolayısıyla biyofilmde oluşan su kanalları nedeniyle porlaşmanın arttığına işaret etmektedir [13]. Nitekim SEM görüntüleri de özellikle 3. ay'da biyofilmin daha heterojen ve kompleks bir yapıya sahip olduğunu ve porların büyüklüğünün arttığını göstermektedir (Şekil 4).…”
Section: Bulgular Ve Tartişma (Findings and Discussion)unclassified
“…At present, most of the research focusses on studying SRB-induced corrosion at a specific pH, commonly the optimum pH for bacteria to grow [2,9,[12][13][14][15][16][17][18][19][20][21][22] which is about 7.4. However, pH of environments can play an important role in microbial corrosion [4,23].…”
Section: Introductionmentioning
confidence: 99%