2009
DOI: 10.1007/s11947-009-0269-9
|View full text |Cite
|
Sign up to set email alerts
|

Effects of Characteristics Changes of Collagen on Meat Physicochemical Properties of Beef Semitendinosus Muscle during Ultrasonic Processing

Abstract: Low-frequency and high-power ultrasound (40 kHz, 1,500 W) was tested for its effects on the characteristics of intramuscular heat-insoluble collagen and meat quality and textural properties of beef semitendinosus muscle. Meat steaks (2.5×5.0×5.0 cm, 100± 5 g) were sonicated for 10, 20, 30, 40, 50, and 60 min, respectively. Characteristics changes of collagen and meat quality and texture were estimated. The results indicated that ultrasound treatment had no significant (P>0.05) effects on L* (lightness) and a* … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
62
0
2

Year Published

2011
2011
2023
2023

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 122 publications
(67 citation statements)
references
References 39 publications
3
62
0
2
Order By: Relevance
“…As regards the influence of ultrasound on altering raw meat texture, similar results were derived in samples immersed in ultrasonic baths at low frequencies (30-40, 34-42, 47 kHz) or high intensities (62,39, 29 W/cm 2 ) where no alteration in beef texture were detected (Lyng et al 1997). Similarly, though at different parameters (40 kHz, 1500 W), Chang et al (2009) observed no differences in control or sonicated samples. Likewise, no improvement was noticed in meat texture regardless of used parameters when using an ultrasonic probe either.…”
Section: Measuring Meat Texturementioning
confidence: 70%
“…As regards the influence of ultrasound on altering raw meat texture, similar results were derived in samples immersed in ultrasonic baths at low frequencies (30-40, 34-42, 47 kHz) or high intensities (62,39, 29 W/cm 2 ) where no alteration in beef texture were detected (Lyng et al 1997). Similarly, though at different parameters (40 kHz, 1500 W), Chang et al (2009) observed no differences in control or sonicated samples. Likewise, no improvement was noticed in meat texture regardless of used parameters when using an ultrasonic probe either.…”
Section: Measuring Meat Texturementioning
confidence: 70%
“…A more recent report by Chang, Xu, Zhou, Li, & Huang (2012) indicated that applying power ultrasound (40 kHz, 1500 W) to semitendinosus beef muscle for 10,20,30,40,50, and 60 min A C C E P T E D M A N U S C R I P T…”
Section: Tendernessmentioning
confidence: 99%
“…[14][15][16] The texture profile analysis (TPA) has been used for the textural evaluation of a wide range of food and vegetables. [17][18][19][20] Textural properties of whole berry depend on different characteristics like cell-wall composition, cell structure, and pulp turgescence, and, therefore, this mechanical test can be useful to follow grape ripening. [21] A complete texture evaluation may be difficult due to the numerous parameters involved.…”
Section: Introductionmentioning
confidence: 99%