In this work, the dependence of the bulk etches rate VB for CR-39detector on thetemperature T, etching time t and concentration N of the NaOH etchant solution has been studied fordetectors material types PADC. The concentration, etching time, temperatureand other conditions havebeen varied in the ranges (5.25-8.25) N, (1-5) hand (60-80) °C for PADC respectively. In this case, the thickness of material removed by etching ranges from 0.20 to 6.10𝜇m/hr for CR-39detector.The 6.25 N NaOH solution at 70°C with etching time 3 hours represents the optimum etching condition for nuclear detector CR-39.