2016
DOI: 10.1007/s10068-016-0166-8
|View full text |Cite
|
Sign up to set email alerts
|

Effects of gardenia seed, green tea, and cactus pear in rice batter on the chemical quality of lotus root bugak and frying oil

Abstract: This study investigated the effects of the addition of gardenia seed, green tea, or cactus pear () to rice batter at 10% on the lipid oxidation, pigments, antioxidants, and antioxidant activity of lotus root and frying oil. Lipid oxidation was evaluated based on the conjugated dienoic acid and-anisidine values. Lipid oxidation and tocopherol degradation were significantly reduced in the gardenia seed-added and frying oil, whereas the cactus pear-added and frying oil showed an increase. The addition of green te… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2017
2017
2020
2020

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(4 citation statements)
references
References 24 publications
(27 reference statements)
0
4
0
Order By: Relevance
“…Tocopherol contents of frying oil were determined using the calibration curves of standards using a YL 9100 HPLC (Younglin Co. Ltd.) with a l-porasil TM column (3.9 9 300 mm, 10 lm i.d., Waters Co., Milford, MA, USA) and a fluorescence detector (excitation 290 nm, emission 330 nm). The eluent was a mixture of n-hexane and isopropanol (99.8:0.2, v/v) at 2 mL/min [12]. Polyphenol contents were determined by the Folin-Ciocalteu method at 725 nm [12] and represented as caffeic acid equivalent.…”
Section: Determination Of Antioxidants and Pigments Of Frying Oil Andmentioning
confidence: 99%
See 3 more Smart Citations
“…Tocopherol contents of frying oil were determined using the calibration curves of standards using a YL 9100 HPLC (Younglin Co. Ltd.) with a l-porasil TM column (3.9 9 300 mm, 10 lm i.d., Waters Co., Milford, MA, USA) and a fluorescence detector (excitation 290 nm, emission 330 nm). The eluent was a mixture of n-hexane and isopropanol (99.8:0.2, v/v) at 2 mL/min [12]. Polyphenol contents were determined by the Folin-Ciocalteu method at 725 nm [12] and represented as caffeic acid equivalent.…”
Section: Determination Of Antioxidants and Pigments Of Frying Oil Andmentioning
confidence: 99%
“…The eluent was a mixture of n-hexane and isopropanol (99.8:0.2, v/v) at 2 mL/min [12]. Polyphenol contents were determined by the Folin-Ciocalteu method at 725 nm [12] and represented as caffeic acid equivalent. Chlorophyll and carotenoid contents were quantified using calibration curves of standards using a YL 9100 HPLC (Younglin Co., Ltd.) [12].…”
Section: Determination Of Antioxidants and Pigments Of Frying Oil Andmentioning
confidence: 99%
See 2 more Smart Citations