PES T&D 2012 2012
DOI: 10.1109/tdc.2012.6281595
|View full text |Cite
|
Sign up to set email alerts
|

Effects of GIC on power transformers and power systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
37
0
4

Year Published

2015
2015
2023
2023

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 85 publications
(43 citation statements)
references
References 7 publications
2
37
0
4
Order By: Relevance
“…We considered transformers with either five or three limbs. In three-limb transformers, the change in flux due to GIC is smaller than for five-limb transformers (Girgis et al, 2012). Our simulations show no voltage instabilities for the system when all transformers are three-limbed.…”
Section: Resultsmentioning
confidence: 64%
“…We considered transformers with either five or three limbs. In three-limb transformers, the change in flux due to GIC is smaller than for five-limb transformers (Girgis et al, 2012). Our simulations show no voltage instabilities for the system when all transformers are three-limbed.…”
Section: Resultsmentioning
confidence: 64%
“…Next, I h2 is mapped into an effective GIC per phase. For a relative wide range of GIC amplitudes (up to a 100 Amps per phase), a linear relationship is reasonable; see (7). For higher amplitudes of GIC, the third order polynomial in (8) …”
Section: Harmonic Monitoring Methodologymentioning
confidence: 88%
“…Dominion's EHV fleet of power transformers consists of single-phase, core/shell designed, 500/230 kV, 280MVA auto-transformers. A comprehensive analysis for different core configurations can be found in [1,[6][7][8]. Fig.…”
Section: B Harmonic Spectrum Of Transformer Magnetizing Current Durimentioning
confidence: 99%
“…Istovremeno transformator se greje i u krajnjem slučaju, ako je DC struja velika, termički se razara. Orijentacije radi, treba reći da struja do oko 20 A, što odgovara niskom nivou geomagnetske struje, izaziva porast temperature transformatora za samo 1 o C [10]. Sa druge strane, tipični impuls GIC iznosi 400 A i traje nekoliko minuta.…”
Section: Slika 2 -Način Ulaska Gic U Elektroenergetski Sistemunclassified
“…oblik AC struje, [10] Posledice uticaja GIC-a zavise i od tipa energetskog transformatora. Za određeni transformator maksimalna dozvoljena DC struja kroz neutral zavisi od više faktora, napr.…”
Section: Slika 3 -Uz Objašnjenje Uticaja DC Struje Na Talasniunclassified