Public reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing this collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS.
REPORT DATE (DD-MM-YYYY)
12-01-2008
REPORT TYPE
Technical Report
DATES COVERED (From -To
ABSTRACTThe purpose of this study was to determine if using the Core Control™ Rapid Thermal Exchange (RTX), a commercial palm cooling device, during active rest periods of multiple set training, is an effective means to increase performance. Ten subjects completed three interval running tests on a human powered treadmill. In those performances subjects completed eight 30-second intervals at a hard/fast pace followed by a 90-second walking or light jogging recovery period. During the recovery period, the subjects placed their hand on one of three media: the RTX held at 15°C (R); a 15°C standard refrigerant gel pack (P), or nothing at all (C.) Although there were differences in core temperature (T c) , subjective heat stress ratings, distance and power generated between intervals, there were no significant differences found between treatments for any of these variables nor was the interaction effect of interval*treatment found to be significant. We conclude that the RTX, in its current iteration, is ineffective at improving performance and/or mitigating thermal stress during high-intensity intermittent exercise.
SUBJECT TERMSCore Control™ Rapid Thermal Exchange, palm cooling device, thermal stress Distribution A: Approved for public release; distribution unlimited.ii
THIS PAGE LEFT INTENTIONALLY BLANKDistribution A: Approved for public release; distribution unlimited.iii viii Executive Summary
TABLE OF CONTENTS
Purpose:The purpose of this study was to determine if using the CoreControl™ Rapid Thermal Exchange (RTX), a commercial palm cooling device, during active rest periods of multiple set training, is an effective means to increase performance. Our hypothesis was that use of the RTX would lower or slow increase in core temperature (T c ), during activity, resulting in greater work and/or training volume per exercise session.
Methods:Ten volunteers (5 male, 5 female) participated in this study. Each volunteer completed four sessions. Session one comprised of a medical examination followed by a VO 2 max test administered via t...