2020
DOI: 10.1016/j.ajo.2020.07.005
|View full text |Cite
|
Sign up to set email alerts
|

Effects of Induced Astigmatism on Spectral Domain-OCT Angiography Quantitative Metrics

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
15
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(15 citation statements)
references
References 50 publications
0
15
0
Order By: Relevance
“…Small amount of VD changes has been reported for 1 D of astigmatism increase. 30 Signal strength can affect accurate data analysis. 31 In fact, for accurate data analysis, RTVue (Optovue, Fremont, CA) recommends $45 in the signal strength index for macular patterns and $35 for retinal scanning, on a scale from 0 to 100.…”
Section: Discussionmentioning
confidence: 99%
“…Small amount of VD changes has been reported for 1 D of astigmatism increase. 30 Signal strength can affect accurate data analysis. 31 In fact, for accurate data analysis, RTVue (Optovue, Fremont, CA) recommends $45 in the signal strength index for macular patterns and $35 for retinal scanning, on a scale from 0 to 100.…”
Section: Discussionmentioning
confidence: 99%
“…Previous studies found that averaging OCTA images could improve vessel clarity that might enhance accurate acquisition of OCTA metrics. 13,25 Uji et al 26 reported that averaging three OCTA frames resulted in signi cant improvement, while averaging ve frames could result in almost identical ndings. Clinically, automated averaging of several OCTA metrics for an overall result is not available from any proprietary software.…”
Section: Discussionmentioning
confidence: 99%
“…Most built-in auto-focus systems are limited to correct spherical defocus. Jung et al 13 found that vessel length density (VD) could be reduced by 0.5mm −1 per diopter of induced with-the-rule astigmatism.…”
Section: Introductionmentioning
confidence: 99%
“…This could be due to the protocol using an average from three OCTA measurements. Previous studies found that averaging OCTA images could improve vessel clarity that might enhance accurate acquisition of OCTA metrics 13 , 25 . Uji et al 26 reported that averaging three OCTA frames resulted in significant improvement, while averaging five frames could result in almost identical findings.…”
Section: Discussionmentioning
confidence: 99%
“…Most built-in auto-focus systems are limited to correct spherical defocus. Jung et al 13 found that vessel length density (VD) could be reduced by 0.5 mm −1 per diopter of induced with-the-rule astigmatism.…”
Section: Introductionmentioning
confidence: 99%