1985
DOI: 10.1002/cjce.5450630306
|View full text |Cite
|
Sign up to set email alerts
|

Effects of interaction between circulating or oscillating droplets on drop formation, free fall, and mass transfer

Abstract: The effects of interaction between circulating or oscillating droplets on drop formation, terminal velocity, and the continuous phase mass transfer coefficient during free fall were studied. To examine the mass transfer coefficient during free fall both end effects were eliminated by subtracting the mass transferred in a short column from that transferred in a long column. A correlation for the prediction of drop volume based on the equations of Scheele and Meister (1968) for non‐jetting drops, and of Meister … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
14
0

Year Published

1992
1992
2016
2016

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 21 publications
(15 citation statements)
references
References 21 publications
1
14
0
Order By: Relevance
“…The distance apart between two consecutive droplets was large enough ( > 60 mm) so that fluid motion was dampened before the next droplet arrives. Thus, interactions between drops should be negligible (Skelland and Vasti, 1985). Three samples were taken in each run and then analyzed by gas chromatography (GC7900).…”
Section: Setup and Proceduresmentioning
confidence: 99%
“…The distance apart between two consecutive droplets was large enough ( > 60 mm) so that fluid motion was dampened before the next droplet arrives. Thus, interactions between drops should be negligible (Skelland and Vasti, 1985). Three samples were taken in each run and then analyzed by gas chromatography (GC7900).…”
Section: Setup and Proceduresmentioning
confidence: 99%
“…Single drop injections were adjusted to make drops more than 6 cm apart. Skelland and Vasti [22] have reported that interactions can be ignored for drops apart by at least 6 cm. Samples (6 cm 3 ) were withdrawn from the collected dispersed phase at the top to determine solute concentration using potentiometric titration.…”
Section: Preparation Of Nanofluidmentioning
confidence: 99%
“…The same results were obtained. Skelland and Vasti (1985) have experimentally investigated the mass transfer coefficient on the continuous phase side by using one and three drop streams in a stagnant liquid. They showed that vertical interaction of drops caused reduction in mass transfer coefficient, whereas the effects of horizontal interaction were found to be negligible.…”
Section: Y-y Huang a N D S M Lumentioning
confidence: 99%