2012
DOI: 10.1016/j.measurement.2011.11.007
|View full text |Cite
|
Sign up to set email alerts
|

Effects of particle charging on electrical capacitance tomography system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 17 publications
(7 citation statements)
references
References 16 publications
0
7
0
Order By: Relevance
“…In EIT the spatial distribution of the electrical conductivity is reconstructed from the boundary data collected by an alternating current injection at the domain boundary. In some applications the electrical permittivity of the DUT is reconstructed from the voltage current data collected at the boundary and the imaging modality is called electrical capacitance tomography (ECT) [ 125 , 133 , 167 , 168 ] which is generally used in industrial process application and mechanical and material engineering. The electrical resistivity of the domain under test is sometimes reconstructed from the boundary data generated by a direct current injection in industrial process imaging, civil structure imaging, subsurface imaging, and other applications of geotechnology.…”
Section: Electrical Impedance Tomography (Eit)mentioning
confidence: 99%
“…In EIT the spatial distribution of the electrical conductivity is reconstructed from the boundary data collected by an alternating current injection at the domain boundary. In some applications the electrical permittivity of the DUT is reconstructed from the voltage current data collected at the boundary and the imaging modality is called electrical capacitance tomography (ECT) [ 125 , 133 , 167 , 168 ] which is generally used in industrial process application and mechanical and material engineering. The electrical resistivity of the domain under test is sometimes reconstructed from the boundary data generated by a direct current injection in industrial process imaging, civil structure imaging, subsurface imaging, and other applications of geotechnology.…”
Section: Electrical Impedance Tomography (Eit)mentioning
confidence: 99%
“…The low and high relative permittivity for calibration materials inside the sensor are 1.0 and 4.0, respectively. In reference [ 14 ], the author drew a conclusion that the greater capacitance differences are produced on the electrode-pairs whose detection electrodes are closer to the charge. Among these electrode-pairs, the greatest electrostatic effect exists on the adjacent ones near the charge.…”
Section: Effects Of Electrification Phenomenon On Ect Using Simulamentioning
confidence: 99%
“…Kanazawa et al [ 13 ] researched the generation and accumulation mechanism of the charge on the inner surface of a powder transport pipe and drew a conclusion that the charge density and polarity actually depended on the successive number of tests and the pipe material. Gao et al [ 14 ] investigated the electrostatic effect on alternating current (AC)-based ECT by simulations and experiments, and an ECT combined with an electrostatic tomography system (EST) was used to verify theoretical analysis. These work proved the fact that particle charge has influences on the capacitance measurement.…”
Section: Introductionmentioning
confidence: 99%
“…The need to analyse the interaction between modalities (e.g. the effect of particle charging) that may adversely affect image quality was also indicated (Gao et al, 2012).…”
Section: Possibilities Of Temperature Distribution Analysis Using Ectmentioning
confidence: 99%