2018
DOI: 10.1021/acs.iecr.8b01019
|View full text |Cite
|
Sign up to set email alerts
|

Effects of Piecewise Electric Field Operation on Sludge Dewatering: Phenomena and Mathematical Model

Abstract: Electro-dewatering (EDW) is an energy-efficient method for sludge dewatering. In this study, effects of piecewise electric field operation on EDW were investigated by experiments and simulation. Operational parameters were studied mainly in terms of sludge resistance variation during electro-dewatering process, which were evaluated by linear sweep voltammetry (LSV) analysis. Simulation of the sludge cake electro-dewatering processes was developed and validated, based upon timedependent experimental data of el… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 15 publications
(3 citation statements)
references
References 28 publications
0
3
0
Order By: Relevance
“…The dry solid DS concentration of the conditioned sludge by the electrochemical-Fenton process was increased from 2.3% to 41%. Furthermore, the estimated cost of conditioning using this method is $41.82 USD/t DS . The electrochemical-Fenton has fewer limitations than other methods (Fenton, Fenton-lime, and FeCl 3 -lime), so it can be considered as a new alternative to wastewater industries.…”
Section: The Methods Of Sludge Conditioning For Dehydrationmentioning
confidence: 99%
See 1 more Smart Citation
“…The dry solid DS concentration of the conditioned sludge by the electrochemical-Fenton process was increased from 2.3% to 41%. Furthermore, the estimated cost of conditioning using this method is $41.82 USD/t DS . The electrochemical-Fenton has fewer limitations than other methods (Fenton, Fenton-lime, and FeCl 3 -lime), so it can be considered as a new alternative to wastewater industries.…”
Section: The Methods Of Sludge Conditioning For Dehydrationmentioning
confidence: 99%
“…Furthermore, the estimated cost of conditioning using this method is $41.82 USD/t DS. 193 The electrochemical-Fenton has fewer limitations than other methods (Fenton, Fentonlime, and FeCl 3 -lime), so it can be considered as a new alternative to wastewater industries.…”
Section: Conditioner Sodium Persulfate Na 2 S 2 O 8 (Sps) Combined Wi...mentioning
confidence: 99%
“…The key factor of the sludge dewatering problem is the extracellular polymeric substances (EPSs) and the oxygen-containing groups in it, causing the hydrophilicity of sludge. Methods have been conducted to improve sludge dewaterability, for example, electric field, flocculant, , cationic surfactant, biomass and advanced oxidation process (AOP), , acidification and ultrasound, and hydrothermal treatment. , …”
Section: Introductionmentioning
confidence: 99%