1960
DOI: 10.1063/1.1731276
|View full text |Cite
|
Sign up to set email alerts
|

Effects of Pressure on Proton Spin-Lattice Relaxation in Several Degassed Organic Liquids

Abstract: The hydrogen nuclear magnetic relaxation time (T1) for degassed samples of several organic liquids has been measured, by a transient method, at pressures up to 1400 kg/cm2, primarily for comparison with results obtained without degassing. Certain of the liquids were investigated, without degassing, by Benedek and Purcell, who concluded that T1 decreases under pressure less rapidly than the rates of translational processes (fluidity and diffusion). The present results confirm this for degassed methyl iodide and… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
4
0

Year Published

1961
1961
1987
1987

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 31 publications
(4 citation statements)
references
References 11 publications
0
4
0
Order By: Relevance
“…In more complex liquids, dependence of relaxation times on concentra tion, temperature, and pressure indicate participation phenomena associated with mutual rotational viscosity (83) and intermolecular dipolar interactions (84,85).…”
Section: Structure and Motion In Solidsmentioning
confidence: 99%
“…In more complex liquids, dependence of relaxation times on concentra tion, temperature, and pressure indicate participation phenomena associated with mutual rotational viscosity (83) and intermolecular dipolar interactions (84,85).…”
Section: Structure and Motion In Solidsmentioning
confidence: 99%
“…It is, therefore, necessary to remove oxygen from the liquid sample in order to study T I of the pure liquid. In addition to methods involving bubbling of helium, distillation under vacuum, or freezepumpthaw techniques (1)(2)(3)(4)(5), misch metal (6) and barium (7) have been used for removing oxygen from liquid samples so that T I could be measured in pure liquids. Magnesium (1) has also been used to degas in certain instances but its use as a getter has not been investigated in any detail.…”
mentioning
confidence: 99%
“…In the former case, the reference frequency is precisely one-half that of the power line and the usual benefits accrue. 4 For operation at frequencies other than 30 Hz, the standard hybrid CJT--multivibrator timing circuit 5 is used because of its simplicity and excellent frequency stability.…”
mentioning
confidence: 99%