Effects of Sampling Conditions and Environmental Factors on Fecal Volatile Organic Compound Analysis by an Electronic Nose Device

Abstract: Prior to implementation of volatile organic compound (VOC) analysis in clinical practice, substantial challenges, including methodological, biological and analytical difficulties are faced. The aim of this study was to evaluate the influence of several sampling conditions and environmental factors on fecal VOC profiles, analyzed by an electronic nose (eNose). Effects of fecal sample mass, water content, duration of storage at room temperature, fecal sample temperature, number of freeze–thaw cycles and effect o… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
38
1

Year Published

2017
2017
2022
2022

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 29 publications
(43 citation statements)
references
References 51 publications
1
38
1
Order By: Relevance
“…Fecal VOC analysis was performed using an electronic nose device (Cyranose 320, Smiths detection, Pasadena, CA). Sampling and measurement conditions were in accordance with the methods described in previous studies on fecal VOC analysis conducted by our research group (10,12,(16)(17)(18). In summary, approximately 0.2 g feces was transferred into a 3 ml sealed vacutainer (BD vacutainer, Belliver Industrial Estate, Plymouth, UK) and gradually heated to room temperature for 30 min, allowing fecal VOCs to fill the headspace.…”
Section: Fecal Voc Analysis By Electronic Nosementioning
confidence: 99%
“…Fecal VOC analysis was performed using an electronic nose device (Cyranose 320, Smiths detection, Pasadena, CA). Sampling and measurement conditions were in accordance with the methods described in previous studies on fecal VOC analysis conducted by our research group (10,12,(16)(17)(18). In summary, approximately 0.2 g feces was transferred into a 3 ml sealed vacutainer (BD vacutainer, Belliver Industrial Estate, Plymouth, UK) and gradually heated to room temperature for 30 min, allowing fecal VOCs to fill the headspace.…”
Section: Fecal Voc Analysis By Electronic Nosementioning
confidence: 99%
“…None of the participating centers administered probiotics routinely. The current study was nested in an ongoing study on the identification of early diagnostic biomarkers for NEC and LOS [9]. In that study, fecal samples and clinical data were collected (if applicable on a daily base) from infants born at a GA ≤30 weeks, up to 28 days’ postnatal age (Table 1).…”
Section: Methodsmentioning
confidence: 99%
“…The scats were collected using one container per individual and were kept frozen until use. We cannot exclude the possibility that freezing the fox scat altered its compounds (Berkhout et al, 2016), but assumed that this effect was constant on all samples. We used scat from one individual per area to avoid pseudoreplication (Kroodsma, Byers, Goodale, Johnson, & Liu, 2001).…”
Section: Methodsmentioning
confidence: 99%