Effects of varying material properties on the load deformation characteristics of heel cushions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
34
0
1

Year Published

2010
2010
2023
2023

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 34 publications
(38 citation statements)
references
References 19 publications
3
34
0
1
Order By: Relevance
“…For this reason, the ability of different cushioning materials to uniformly distribute externally applied forces was initially assessed under well controlled loading conditions using a 3D printed heel model. Similar testing techniques using rigid lasts or compression plates have been used before in the broader area of footwear biomechanics21 but not to quantify the ability of cushioning materials to uniformly distribute plantar loading.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…For this reason, the ability of different cushioning materials to uniformly distribute externally applied forces was initially assessed under well controlled loading conditions using a 3D printed heel model. Similar testing techniques using rigid lasts or compression plates have been used before in the broader area of footwear biomechanics21 but not to quantify the ability of cushioning materials to uniformly distribute plantar loading.…”
Section: Discussionmentioning
confidence: 99%
“…Considering their role, it is no surprise that the effectiveness of therapeutic footwear and/or orthoses is strongly dependent on the mechanical characteristics of the materials that are used to offer cushioning, with stiffness being among the most critical characteristics 6,9,12,15,20,21…”
Section: Introductionmentioning
confidence: 99%
“…Several authors performed mechanical tests with the demand to mimic natural running. But the mechanical input parameters used in these studies showed strong differences among each other (Walker 1998, Sun et al 2008 as well as compared to biomechanical studies. Comparing machine-simulated running and in vivo loaded shoes, differences up to 25% were found (Cook et al 1985).…”
Section: Introductionmentioning
confidence: 89%
“…These values were representative of impact force observed during running. To examine stable characteristics, we analyse only the tenth cycle with the previous ones that are being used to stabilise the mechanical behaviour of the material (Sun et al, 2008).…”
Section: Mechanical Experimentationmentioning
confidence: 99%