Efficacy comparison of Kirschner-wire tension band combined with patellar cerclage and anchor-loop plate in treatment of inferior patellar pole fracture

Abstract: Objective: This study aimed to compare the biomechanical stability and clinical efficacy of the Kirschner-wire (K-wire) tension band combined with patellar cerclage and an anchor-loop plate (ALP) in treating inferior-pole patellar fracture.Methods: The finite element model was established to analyze the mechanical properties of a K-wire tension band combined with patellar cerclage and ALP fixation in the treatment of inferior patellar pole fracture. The clinical data of 49 patients with patellar inferior-pole … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
10
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 8 publications
(11 citation statements)
references
References 34 publications
1
10
0
Order By: Relevance
“…Rigid fixation devices included those using plates and screws ( n = 326, 8 studies; Fig. 1A) [6, 9, 18, 23, 27, 30–32] and concentrators ( n = 119, 2 studies; Fig. 1B) [4, 25].…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Rigid fixation devices included those using plates and screws ( n = 326, 8 studies; Fig. 1A) [6, 9, 18, 23, 27, 30–32] and concentrators ( n = 119, 2 studies; Fig. 1B) [4, 25].…”
Section: Resultsmentioning
confidence: 99%
“…Mixed devices included those fixed using TBW ( n = 294, 12 studies; Fig. 1F) [2, 3, 6, 8, 16, 22, 26, 35, 41, 44, 46, 48] or a similar technique with or without other augmentation ( n = 22, 1 study) [24]. These devices combined rigid fixation devices (e.g., interosseous K‐wire) and tensile fixation devices (e.g., figure‐8 wire).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…92 Du et al compared the clinical effects and mechanical properties of different treatment methods for inferior pole fractures of the patella. 93 The anchor-loop plate had better biomechanical stability and clinical effect than the Kirschner wire tension band combined with patellar cerclage. 93 Overall, finite element analysis of the knee joint applied to fractures and bone defects can simulate the biomechanical results well and has good prospects for the research and treatment of fractures and bone defects.…”
Section: Bone Defects and Fracturesmentioning
confidence: 92%
“…Du et al . compared the clinical effects and mechanical properties of different treatment methods for inferior pole fractures of the patella 93 . The anchor‐loop plate had better biomechanical stability and clinical effect than the Kirschner wire tension band combined with patellar cerclage 93 …”
Section: Application and Characteristicsmentioning
confidence: 99%