2008
DOI: 10.1038/eye.2008.320
|View full text |Cite
|
Sign up to set email alerts
|

Efficacy of portable X-ray in identifying retained suture needles in ophthalmologic cases

Abstract: Aims To evaluate the role and efficacy of portable X-ray in reliably identifying retained suture needles in ophthalmologic surgical cases. Methods Ophthalmologic 10À0 nylon suture needles were placed into 10 of 20 porcine eyes positioned within the orbit of a human skull. Portable, plain film radiographs were taken of all eyes with a C-arm fluoroscopy machine. The films were reviewed by six ophthalmologists and six radiologists who were blinded to the presence or absence of needles, as well as the number of ne… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
9
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(10 citation statements)
references
References 11 publications
0
9
0
Order By: Relevance
“…Yes, there is evidence identifying which suture needle lengths can be located on radiographic images but it is conflicting 1‐7 . Additionally, the evidence is limited by several factors, including a focus on abdominal imaging, the use of acrylic torsos and animals, the placement of the needles (eg, blinded, nonblinded), inconsistencies among the personnel reviewing the images, differences in reporting of needle length or suture size (eg, 10‐mm, 9‐0), and publication before 2016.…”
Section: Identifying Retained Suture Needles On Radiographic Imagesmentioning
confidence: 99%
See 2 more Smart Citations
“…Yes, there is evidence identifying which suture needle lengths can be located on radiographic images but it is conflicting 1‐7 . Additionally, the evidence is limited by several factors, including a focus on abdominal imaging, the use of acrylic torsos and animals, the placement of the needles (eg, blinded, nonblinded), inconsistencies among the personnel reviewing the images, differences in reporting of needle length or suture size (eg, 10‐mm, 9‐0), and publication before 2016.…”
Section: Identifying Retained Suture Needles On Radiographic Imagesmentioning
confidence: 99%
“…In a study of the use of a portable x‐ray device as a means to identify retained suture needles, researchers found low levels of sensitivity and specificity when both ophthalmologists and radiologists reviewed the radiographs for retained needles from 10‐0 suture placed in porcine eyes 5 . Small needles (eg, from a 10‐0 suture) used during ophthalmology procedures may be lost during transfer to and from the operative site.…”
Section: Identifying Retained Suture Needles On Radiographic Imagesmentioning
confidence: 99%
See 1 more Smart Citation
“…Institutions, including our own, enforce a retrieval protocol that utilizes intra-operative x-ray imaging to detect RSIs (Kieval et al, 2009;…”
Section: Introductionmentioning
confidence: 99%
“…The incidence of retained surgical items (RSI) is estimated to be one in every 1000–18,000 surgeries (Weprin, Crocerossa, et al, 2021). Institutions, including our own, enforce a retrieval protocol that utilizes intra‐operative x‐ray imaging to detect RSIs (Kieval et al, 2009; Macilquham et al, 2003; McCombe et al, 2021; Yanagawa et al, 2018). Our institution's protocol requires the operating surgeon to pause wound closure and proceed with close examination of the wound, whereas the operating room (OR) staff search the nonsterile field.…”
Section: Introductionmentioning
confidence: 99%