Abstract: Study DesignThis retrospective study was conducted to determine the safety and efficacy of titanium cage reconstruction and anterior plating after thoracolumbar corpectomy.PurposeTo study the clinical and radiological outcome of anterior column reconstruction after thoracolumbar corpectomy.Overview of LiteratureAnterior column reconstruction aims to optimize neural decompression with adequate stabilization.MethodsA series of 16 patients underwent reconstruction after thoracolumbar corpectomy to treat injury du… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
4
0
1

Year Published

2017
2017
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(6 citation statements)
references
References 26 publications
1
4
0
1
Order By: Relevance
“…We have preferred the allograft using titanium mesh in order to avoid additional autograft harvesting with potential complications. According to previous studies, titanium mesh provide better anterior column support and lower kyphosis angle loss rate [11,20,21,32,[35][36][37]. Similarly, this study has also concluded that the correction of kyphosis was achieved with satisfactory postoperative cobb angle and acceptable loss of correction.…”
Section: Discussionsupporting
confidence: 67%
“…We have preferred the allograft using titanium mesh in order to avoid additional autograft harvesting with potential complications. According to previous studies, titanium mesh provide better anterior column support and lower kyphosis angle loss rate [11,20,21,32,[35][36][37]. Similarly, this study has also concluded that the correction of kyphosis was achieved with satisfactory postoperative cobb angle and acceptable loss of correction.…”
Section: Discussionsupporting
confidence: 67%
“…According to previous studies, titanium mesh provide better anterior column support and lower kyphosis angle loss rate. [11,20,21,32,[35][36][37] Similarly, this study has also concluded that the correction of kyphosis was achieved with satisfactory postoperative cobb angle and acceptable loss of correction. The correction rate and kyphosis angle loss rate as other evaluation indicators for the posterior xation effectiveness and the anterior bony fusion rate were also summarized.…”
Section: Resultsmentioning
confidence: 74%
“…Apart from the ENT surgery, they are well known in general surgery, orthopaedics or maxillofacial surgery [20][21][22][23][24][25][26][27]. Such widespread use of titanium can be attributed to its favorable mechanical properties, corrosive resistance, biocompatibility and biotolerance [7,28].…”
Section: Discussionmentioning
confidence: 99%