Efficiency Assessment of Five Types of Photovoltaic Modules Installed on a Fixed and on a Dual-Axis Solar-Tracked Platform

Abstract: A solution to increase the electrical output of the photovoltaic systems relies on solar tracking mechanisms that increase the amount of received solar energy. The experimental results obtained during a monitoring period of one year are comparatively presented in the paper for five types of photovoltaic modules installed on a fixed platform (as reference) and on a dual-axis solar tracking platform in the Renewable Energy Systems and Recycling R&D Centre of the Transilvania University of Brasov, Romania. Th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
3
0
1

Year Published

2023
2023
2024
2024

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 33 publications
0
3
0
1
Order By: Relevance
“…Tracking System Type Control Strategy Location (Latitude/Longitude) Energy Gain [4] dual-axis open-loop 45.657974 N/25.601198 E 41.45% [5] dual-axis closed-loop 12.873498 N/80.219866 E 27% [6] dual-axis open-loop 33.838 N/−6.083 W 35.71% [7] dual-axis close-loop 29.571858 N/57.301047 E 31.8% [8] single-axis open-loop −29.72404 S/−53.71081 W 25.76% [9] single-axis open-loop 25.037519 N/121.563679 E 24.2% [10] dual-axis closed-loop 12.824342 N/101.216274 E 44.89% [11] dual-axis open-loop 45.657974 N/25.601198 E 29.6% [12] single|dual-axis closed-loop 26.43442 N/50.10326 E 18.73%|28.98% [13] single|dual-axis closed-loop 13.072090 N/80.201859 E 20%|40% [14] dual-axis open-loop −29.68605 S/−53.80692 W 20.87% [15] dual-axis open-loop 13.82184 N/100.51316 E 20.1% [16] single|dual-axis open-loop 45.957481 N/15.494230 E 30.04%|39.96% [17] dual-axis open-loop 3.023284 N/101.715903 E 26.9% [18] dual-axis open-loop −5.138724 S/119.443643 E 56.67%…”
Section: Referencesmentioning
confidence: 99%
See 2 more Smart Citations
“…Tracking System Type Control Strategy Location (Latitude/Longitude) Energy Gain [4] dual-axis open-loop 45.657974 N/25.601198 E 41.45% [5] dual-axis closed-loop 12.873498 N/80.219866 E 27% [6] dual-axis open-loop 33.838 N/−6.083 W 35.71% [7] dual-axis close-loop 29.571858 N/57.301047 E 31.8% [8] single-axis open-loop −29.72404 S/−53.71081 W 25.76% [9] single-axis open-loop 25.037519 N/121.563679 E 24.2% [10] dual-axis closed-loop 12.824342 N/101.216274 E 44.89% [11] dual-axis open-loop 45.657974 N/25.601198 E 29.6% [12] single|dual-axis closed-loop 26.43442 N/50.10326 E 18.73%|28.98% [13] single|dual-axis closed-loop 13.072090 N/80.201859 E 20%|40% [14] dual-axis open-loop −29.68605 S/−53.80692 W 20.87% [15] dual-axis open-loop 13.82184 N/100.51316 E 20.1% [16] single|dual-axis open-loop 45.957481 N/15.494230 E 30.04%|39.96% [17] dual-axis open-loop 3.023284 N/101.715903 E 26.9% [18] dual-axis open-loop −5.138724 S/119.443643 E 56.67%…”
Section: Referencesmentioning
confidence: 99%
“…Given that the number of tracking steps (n) is a design variable, defined by a predefined variation range during optimization, n ∈ [n min , n max ], to make it possible to automatically update the number of STEP functions in Equation (11), it was chosen to use a conditional "IF" function, having the format below [66]: IF(Function1: Function2, Function3, Function4), (13) where Function1 is the function/expression that ADAMS evaluates: if the value of Func-tion1 is less than 0, IF returns Function2; if the value of Function1 is 0, IF returns Function3; and if the value of Function1 is greater than 0, IF returns Function4. As examples, the forms of Equation ( 11) are presented below for the cases where the range of variation of the number of movement steps is n ∈ [1,2], Equation ( 14), and n ∈ [1,3]…”
Section: Optimal Design Of the Tracking Programmentioning
confidence: 99%
See 1 more Smart Citation
“…Đường cong đặc trưng của PV ở các nhiệt độ khác nhau được thể hiện trong hình 2. Về mặt thực nghiệm, mỗi loại PV có một hệ số nhiệt độ khác nhau, hệ số nhiệt độ của công nghệ m-Si, p-Si, CIGS, CIS, CdTe lần lượt là -0,44; -0,45; -0,38; -0,39; -0,25 (%/ • K) [7].…”
Section: Giới Thiệuunclassified