IEEE 36th Conference on Power Electronics Specialists, 2005.
DOI: 10.1109/pesc.2005.1581635
|View full text |Cite
|
Sign up to set email alerts
|

Efficiency Evaluation in Grid Connected Photovoltaic Energy Conversion Systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
10
0
1

Publication Types

Select...
5
3
1

Relationship

1
8

Authors

Journals

citations
Cited by 23 publications
(11 citation statements)
references
References 6 publications
0
10
0
1
Order By: Relevance
“…The choice of one or another form to connect the PV panels among themselves and to the inverter system will be a determining factor on aspects such as the use of solar radiation, the shading influence or the mismatch losses [17]. Most used PV architectures could be grouped basically in the following four configurations: centralized inverters, string inverters, multi-string inverters and AC modules [18]. Other architectures have been suggested on an experimental basis, but its efficiency has not been proved in real grid tied facilities [19].…”
Section: Pv System Topologiesmentioning
confidence: 99%
“…The choice of one or another form to connect the PV panels among themselves and to the inverter system will be a determining factor on aspects such as the use of solar radiation, the shading influence or the mismatch losses [17]. Most used PV architectures could be grouped basically in the following four configurations: centralized inverters, string inverters, multi-string inverters and AC modules [18]. Other architectures have been suggested on an experimental basis, but its efficiency has not been proved in real grid tied facilities [19].…”
Section: Pv System Topologiesmentioning
confidence: 99%
“…Since the output voltage of the inverter does not vary much, the losses are usually expressed as a quadratic function of power instead of current, such as: P loss = K 0 + K 1 P out + K 2 P 2 out [4]. Conversion losses can be analyzed based on the internal details of the inverter (see for example [5]), but we prefer to take the black-box approach here. Manufacturers usually provide an efficiency profile for a range of power levels which can then be used to estimate the constants in an equation such as the one above.…”
Section: Electrical Conversion Efficiencymentioning
confidence: 99%
“…Thus, it is possible the direct connection between the PV array and the 1F-B converter dc-bus ( Figure 1). Hence, the step-up stage is not needed [27], [28], increasing the overall system efficiency [29].…”
Section: Introductionmentioning