Efficiency improvement due to direct torque and flux three levels three areas control method applied to small hydroelectric power plant

Abstract: Abstract. The paper presents a description of a new DTFC3L3A (direct torque and flux control three levels three areas) control method of induction machine as well as its comparison with the DTC method. The basis for the comparison is the switching frequency of described methods. The proposed method is optimized to reduce number of switchings (which is proportional to switching power losses) in static state, as well as it takes into account the δ angle which makes it possible to obtain a sinusoidal shape of flu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2013
2013
2014
2014

Publication Types

Select...
2
1

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(5 citation statements)
references
References 9 publications
0
5
0
Order By: Relevance
“…5a), but in order to take full advantage of the three-level inverter each of the sectors is divided into four equilateral triangles (Fig. 9a) [13]. This division allows to choose a triangle in which the U * s stator voltage vector is currently located.…”
Section: Dtfc-3l-3am Methodmentioning
confidence: 99%
See 2 more Smart Citations
“…5a), but in order to take full advantage of the three-level inverter each of the sectors is divided into four equilateral triangles (Fig. 9a) [13]. This division allows to choose a triangle in which the U * s stator voltage vector is currently located.…”
Section: Dtfc-3l-3am Methodmentioning
confidence: 99%
“…These variables are defined by Eqs. (8) and (9) [13]. If the projection of the U * s stator voltage vector on the U sec1 vector is shorter than half of vector's U sec1 length, then the U * s vector is located inside triangle 0.…”
Section: Dtfc-3l-3am Methodmentioning
confidence: 99%
See 1 more Smart Citation
“…This can be done using the three-level NPC inverter fed induction motor drive with direct torque control. This control ensures fast dynamic response even at low frequencies [3]. The NPC inverter is one of the most commonly used multilevel inverter topology for driving induction motor at high power applications.…”
Section: Improved Dtc Using Three-level Inverter Topology For Windmentioning
confidence: 99%
“…For a specified value of the torque ripple, the weight and overall dimension of LC filter can be reduced if 3-level inverter is used instead of 2-level [7]. Neutral Point Clamped (NPC) 3-level voltage source inverter is a widely used topology of multilevel inverters [8][9][10].…”
Section: Introductionmentioning
confidence: 99%