Efficiency of low‐contrast detail detectability in fluoroscopic imaging

Abstract: The detectability of a static low-contrast detail in the dynamic fluoroscopic image of a homogeneous phantom was assessed by physical measurement of the signal-to-noise ratio (SNR) and by psychophysical measurement of the human observer detectability index d'. The two-alternative forced-choice method was used for human observer tests. The image data consisted of digitally recorded fluoroscopic image sequences which were displayed in a continuous loop of varying length (1-50 frames) at a rate of 25 frames/s. Hu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
25
0

Year Published

1999
1999
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 23 publications
(25 citation statements)
references
References 28 publications
0
25
0
Order By: Relevance
“…The calculated efficiency (0.44) is in the range obtained by other authors (h 0.5) when applying the same model observer to other types of images. 14,18,29 The agreement between the model and human observer was excellent at the dose range considered in this work (10-250 mA) for both reconstruction algorithms after applying the h factor, as shown in Figure 6.…”
Section: Discussionmentioning
confidence: 78%
See 1 more Smart Citation
“…The calculated efficiency (0.44) is in the range obtained by other authors (h 0.5) when applying the same model observer to other types of images. 14,18,29 The agreement between the model and human observer was excellent at the dose range considered in this work (10-250 mA) for both reconstruction algorithms after applying the h factor, as shown in Figure 6.…”
Section: Discussionmentioning
confidence: 78%
“…28,29 Only the human PC values below this threshold were used to determine the efficiency of the NPWE model observer. In Figure 5, the d9 values for the average human observer are plotted as a function of NPWE models (both squared).…”
Section: Efficiency Calculationmentioning
confidence: 99%
“…6,10,11 Additionally, application of linear observer models to fluoroscopic and angiographic imaging systems has been investigated. [13][14][15][16][17][18][19][20][21][22][23][24][25][26] However, the vast majority of the reports feature investigations on simulated data. [13][14][15][16][17]19,[21][22][23][24][25] Although simulated data have significant merits for system design, data acquired from real imaging systems are required to assess real-world system performance.…”
Section: Introductionmentioning
confidence: 99%
“…Only a few reports describe experiments using real images; however, these investigations did not implement channelized Hotelling observer (CHO) models as described below. 18,20,26 For hardware assessment, the Bayesian ideal observer or the ideal linear observer is desirable. 27 When considering object signal-to-noise ratio (SNR) as the model's figure of merit (FOM), the Hotelling model is the optimal linear observer.…”
Section: Introductionmentioning
confidence: 99%
“…The model observer used in this study has previously been described in detail (8)(9)(10) . In short, The DCsHFs-observer conditional decision variables (eq.1) were needed in (eq.2)…”
Section: Snr 2 Rate Measurements and Analysismentioning
confidence: 99%