2018 IEEE International Conference on High Voltage Engineering and Application (ICHVE) 2018
DOI: 10.1109/ichve.2018.8642229
|View full text |Cite
|
Sign up to set email alerts
|

Efficient PD Monitoring of HV Electrical Systems Using HFCT Sensors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(5 citation statements)
references
References 5 publications
0
2
0
Order By: Relevance
“…These requirements have been considered to design the tests to be implemented in the synthetic PD calibrator. Measurements in real time (1) are needed for continuous PD monitoring in HVDC systems because PD pulses appear mainly during voltage changes, such as voltage polarity reversals and temporary or transient over-voltages as switching and lightning surges.…”
Section: S N S N+1mentioning
confidence: 99%
See 2 more Smart Citations
“…These requirements have been considered to design the tests to be implemented in the synthetic PD calibrator. Measurements in real time (1) are needed for continuous PD monitoring in HVDC systems because PD pulses appear mainly during voltage changes, such as voltage polarity reversals and temporary or transient over-voltages as switching and lightning surges.…”
Section: S N S N+1mentioning
confidence: 99%
“…An inverse double exponential (IDE) function (1) with known α and β parameters and slope zero in its origin can be used to emulate actual PD pulses with arbitrary time parameters T 1 /T 2 . In Figure 3, some different PD pulse waveforms are shown with their associated α and β parameters: (a) a reference PD pulse showing the definition of the time parameters T 1 /T 2 , (b) an asymmetric PD pulse with short front time, (c) an asymmetric PD pulse with a long front time, and (d) a symmetric PD pulse.…”
Section: Pd Pulse Waveforms Generated By Insulation Defectsmentioning
confidence: 99%
See 1 more Smart Citation
“…To appropriately detect PD activity and perform accurate diagnosis, various measuring applications based on electromagnetic methods have been and continue to be developed [ 8 , 9 , 10 , 11 , 12 ]. These applications usually have specific functionalities, such as background noise filters to improve the sensitivity and PD source discrimination, as well as location and defect identification tools [ 3 , 4 , 13 , 14 ]. They also have the capacity to generate assisted or automatic alarms when a critical defect is identified [ 15 ].…”
Section: Introductionmentioning
confidence: 99%
“…When the benefits of using a particular functionality are presented, complex laboratory setups with artificial defects in a certain asset or in test cells are usually used [ 4 , 6 , 14 ]. On other occasions, for this purpose, on-site case studies in real installations have been presented [ 3 , 7 , 11 , 15 ].…”
Section: Introductionmentioning
confidence: 99%