2003
DOI: 10.1016/s0304-3991(02)00317-0
|View full text |Cite
|
Sign up to set email alerts
|

Efficient sampling for three-dimensional atom probe microscopy data

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
100
0

Year Published

2006
2006
2017
2017

Publication Types

Select...
6
4

Relationship

1
9

Authors

Journals

citations
Cited by 155 publications
(100 citation statements)
references
References 7 publications
0
100
0
Order By: Relevance
“…In the analysis of data isoconcentration surfaces and proximity histograms were derived for a voxel of 2 3 nm 3 and a delocalization of 4 nm using CAMECA's IVAS software, which implements methods developed by Hellman et al [35][36][37] Proximity histograms were represented as distance versus carbon at. pct, or the ratio of the number of each elements atoms against the number of iron atoms.…”
Section: Methodsmentioning
confidence: 99%
“…In the analysis of data isoconcentration surfaces and proximity histograms were derived for a voxel of 2 3 nm 3 and a delocalization of 4 nm using CAMECA's IVAS software, which implements methods developed by Hellman et al [35][36][37] Proximity histograms were represented as distance versus carbon at. pct, or the ratio of the number of each elements atoms against the number of iron atoms.…”
Section: Methodsmentioning
confidence: 99%
“…APT data were analyzed with the IVAS ® 3.0 software program (Imago Scientific Instruments, Madison, Wisconsin). The γ'-precipitate/γ-matrix heterophase interfaces were delineated with Al isoconcentration surfaces generated by efficient sampling procedures [20]. Detailed compositional information was obtained with the proximity histogram method [21], and extrapolated to infinite time employing the predictions of classical coarsening models [22].…”
Section: Methodsmentioning
confidence: 99%
“…1, the absence of large density fluctuations between the reconstructed phases demonstrates that the field-evaporation behavior of the two phases is similar. The c/c 0 interfaces are delineated with 9 at.% Al isoconcentration surfaces (approximately the mid-point value between bulk compositions of c and c 0 ) calculated with efficient sampling procedures [31] and parameters [25] that optimize the statistical noise and reduce positional errors. Employing this isoconcentration surface procedure, c 0 -precipitates with radii (determined from the volume-equivalent radius of the best-fit ellipsoid [25]) as small as 0.45 nm (20 detected atoms) are resolved.…”
Section: Methodsmentioning
confidence: 99%