2013
DOI: 10.1002/open.201300022
|View full text |Cite
|
Sign up to set email alerts
|

Efficient Sustainable Tool for Monitoring Chemical Reactions and Structure Determination in Ionic Liquids by ESI‐MS

Abstract: An easy and convenient procedure is described for monitoring chemical reactions and characterization of compounds dissolved in ionic liquids using the well-known tandem mass spectrometry (MS/MS) technique. Generation of wastes was avoided by utilizing an easy procedure for analysis of ionic liquid systems without preliminary isolation and purification. The described procedure also decreased the risk of plausible contamination and damage of the ESI-MS hardware and increased sensitivity and accuracy of the measu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 7 publications
(7 citation statements)
references
References 90 publications
0
7
0
Order By: Relevance
“…The MS spectrometer was equipped with an electrospray-ionization (ESI) source. The operating parameters the following: the ion-spray voltage was 5500 V, the capillary voltage was 40 V, and the capillary temperature was 250 °C. Mass spectra within a mass range of 100–2000 m / z were acquired in positive-ion mode. The compositions of the polyglycerols were identified by measuring their m / z values.…”
Section: Methodsmentioning
confidence: 99%
“…The MS spectrometer was equipped with an electrospray-ionization (ESI) source. The operating parameters the following: the ion-spray voltage was 5500 V, the capillary voltage was 40 V, and the capillary temperature was 250 °C. Mass spectra within a mass range of 100–2000 m / z were acquired in positive-ion mode. The compositions of the polyglycerols were identified by measuring their m / z values.…”
Section: Methodsmentioning
confidence: 99%
“…Because of their unique and flexible properties, ionic liquids find application in numerous fields, including those related to chemical analysis. ILs are employed in electrophoresis, 80,81,815 extraction, 81,85,87,[488][489][490]816,817 gas and liquid chromatography, 80,81,818,819 UV−visible, IR, Raman, and fluorescence spectroscopy, 80,81 NMR, 81,164,165,[167][168][169]820 and mass spectrometry, 80,81,170,821,822 as well as in various sensor systems (Figure 24). 80−82,823−825 Several comprehensive reviews have been published on the topic recently.…”
Section: Ionic Liquids In Biomedical Analyticsmentioning
confidence: 99%
“…835 Among other analytical methods, NMR and mass spectrometry are highly demanded. 164,165,168,170 Thus, UV-light absorbing IL-based matrices were efficiently used in matrix-assisted desorption/ionization mass spectrometry (MALDI-MS) for biosensing bacterial toxins without preliminary separation and purification. 836 As in many other scientific and industrial areas, the tunability of ILs has won them an important place in the field of electrochemical sensors.…”
Section: Ionic Liquids In Biomedical Analyticsmentioning
confidence: 99%
See 1 more Smart Citation
“…The operational stability of Lipozyme 435 under pilot-scale conditions was also investigated by reusing it in the BCR. Electrospray ionization mass spectrum (ESI-MS) which was considered as a quick and convenient tool for a qualitative analysis was employed to analyze the composition of esterification products (Khemchyan et al, 2013).…”
Section: Introductionmentioning
confidence: 99%