2008
DOI: 10.1088/0031-9155/53/18/007
|View full text |Cite
|
Sign up to set email alerts
|

Efficient use of continuous, real-time prostate localization

Abstract: Recent technological advances make it possible to monitor prostate movement during radiation delivery. Using previously published data from 35 patients who underwent continuous localization during prostate cancer treatment, we simulated various interventions to identify the radiation-gating and patient-repositioning strategies that least prolonged the time to complete the daily treatment. Acceptable response protocols were those that resulted in at least 95% of patients' prostates remaining within the planning… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
15
0

Year Published

2009
2009
2012
2012

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(16 citation statements)
references
References 21 publications
1
15
0
Order By: Relevance
“…The assumed baseline parameter values ⌺ = = 3 mm are broadly in line with the values reported in literature for setup to external markers. 21 For image-guided setup, interfraction setup errors will be smaller, but in order to properly account for geometric uncertainties, one should also account for intrafraction motion [22][23][24] and delineation errors. 25 The present work did not go to this level of detail.…”
Section: Discussionmentioning
confidence: 99%
“…The assumed baseline parameter values ⌺ = = 3 mm are broadly in line with the values reported in literature for setup to external markers. 21 For image-guided setup, interfraction setup errors will be smaller, but in order to properly account for geometric uncertainties, one should also account for intrafraction motion [22][23][24] and delineation errors. 25 The present work did not go to this level of detail.…”
Section: Discussionmentioning
confidence: 99%
“…Most methods use implanted markers. Current commercially available 3D position monitoring options include stereoscopic x-ray imaging systems (8,16), which consist of two kV x-ray sources (mounted either on the ceiling or on the gantry) respectively paired with opposed x-ray imagers, and an electromagnetic localization system (Calypso) (3,4,10,11,14). Usage of the first method has to be weighed against the additional kV imaging dose to which patients are exposed.…”
Section: Discussionmentioning
confidence: 99%
“…The prostate is mostly stationary and drifts slowly, with abrupt movement occurring only occasionally (4,(10)(11)(12). Therefore, in contrast with current motion monitoring techniques that seek to accurately and continuously localize a moving target, in a previous study (13), we attempted for the first step to detect only potential motion beyond a predefined threshold.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…15 The prostate is mostly stationary and drifts slowly with abrupt motion occurring only occasionally. [16][17][18][19][20][21][22][23] In contrast with current motion monitoring techniques, which seek to accurately and continuously localize a moving target, we proposed and simulated a "failure" detection strategy 24 to detect in a first step only motion that is potentially beyond a predefined threshold using treatment beam MV imaging, available at no tracking dose cost. The correlative relationship between directional components of prostate motion [17][18][19] was used for the first step estimation.…”
Section: Introductionmentioning
confidence: 99%