“…These procedures also place an economic burden on the facility and delays in utilizing the PET-CT clinical scan equipment. 1 16 22 23 24 27 28 Dealing and handling of radioactivity, either for QC or for clinical scans in nuclear medicine, lead to radiation exposure of the operating radiographer or technologist. Performing daily and weekly QC is one of the unavoidable situations where the operator needs to hold the phantom source filled with radioactivity by hand and position it on the PET scanner.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…These procedures also place an economic burden on the facility and delays in utilizing the PET-CT clinical scan equipment. 1 16 22 23 24 27 28 Dealing and handling of radioactivity, either for QC or for clinical scans in nuclear medicine, lead to radiation exposure of the operating radiographer or technologist. Performing daily and weekly QC is one of the unavoidable situations where the operator needs to hold the phantom source filled with radioactivity by hand and position it on the PET scanner.…”
Section: Discussionmentioning
confidence: 99%
“…Several international bodies and manufacturers have published QC guidelines and recommendations for a PET imaging modality to ensure adequate performance of the systems to achieve accurate qualitative and quantitative outcomes in clinical practice, as well as the frequency of these tests. 1 16 22 23 24 27 28 QC as a segment of a QA program aims to monitor that a system is performing as expected. In order for the PET part to function properly, the detectors and measuring electronics must function properly.…”
Section: Discussionmentioning
confidence: 99%
“…The C i was determined from spherical volumes of interest (VOIs) with diameters matching the respective sphere size (10, 13, 17, 22, 28 and 37 mm) of the IEC phantom spheres, and the C BG was determined from a box-shaped VOI of 150 mm × 15 mm × 170 mm. The image noise was assessed using the coefficient of variation (CV), a widely used parameter for comparison of the noise performance of PET scanners [20,21]. The CV was calculated according to the following equation:…”
Section: Iec Phantom Measurements and Analysis Of Iq Contrast Recover...mentioning
confidence: 99%