2014 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP) 2014
DOI: 10.1109/ceidp.2014.6995817
|View full text |Cite
|
Sign up to set email alerts
|

Electric field evaluation of ±400kV converter quadrivalve corona shields in high altitude area

Abstract: The converter quadrivalve is one of the key devices in a ±400kV converter station valve hall at an altitude of 3820m in western China. The complex structure of quadrivalve may lead to serious electric field distortion when without well-designed shields. Besides, in view of high altitude, corona discharge is easier to occur, which threatens the secure operation of HVDC system. In this paper, the structure of ±400kV converter quadrivalve is introduced. A 3-D electric field calculation model of three quadrivalves… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
3
1
1

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(2 citation statements)
references
References 5 publications
0
2
0
Order By: Relevance
“…The common external characteristic method uses fitting based on test data [4][5][6] and the semiempirical method combines experimental and theoretical research [7,8]: these are regarded as the primary methods for calculating the COV and corona onset field intensity of charged conductors. Peek first proposed a semi-empirical formula suitable for the corona onset condition of a cylindrical conductor based on test data [9]; however, Peek's formula fails to predict the corona onset field intensities of conductors with a large radius of curvature and a non-cylindrical structure.…”
Section: Introductionmentioning
confidence: 99%
“…The common external characteristic method uses fitting based on test data [4][5][6] and the semiempirical method combines experimental and theoretical research [7,8]: these are regarded as the primary methods for calculating the COV and corona onset field intensity of charged conductors. Peek first proposed a semi-empirical formula suitable for the corona onset condition of a cylindrical conductor based on test data [9]; however, Peek's formula fails to predict the corona onset field intensities of conductors with a large radius of curvature and a non-cylindrical structure.…”
Section: Introductionmentioning
confidence: 99%
“…The corona onset characteristics of charged conductors are related not only to the size parameters (ring diameter and pipe diameter) of charged conductors, but also to the environmental parameters (atmospheric pressure, temperature, and humidity) affecting the air ionisation. At present, the research on the corona onset characteristics of charged conductors mainly obtains the corona onset voltage of charged conductors in different sizes and different environments by test [5][6][7][8][9][10]. However, due to the limitation of test conditions, it is difficult to carry out the high voltage test, and the influence mechanisms of the corona onset cannot be revealed from the basic physical process of corona discharge.…”
Section: Introductionmentioning