This study analyzed the temperature distribution in DPF with five partitioned electric heaters. The temperature distribution in DPF is an important design factor for regeneration and durability of filter. The design Factors that influence the temperature distribution in DPF there are several. In this study, the characteristics of temperature distribution in DPF were analyzed according to the following changes. First, the thermal conductivity of the filter was analyzed about effect on the durability of the filter. Second, the length from exhaust manifold to inlet of DPF was analyzed about effect on the temperature distribution in DPF. The boundary conditions of analysis has been verified with comparison to the results of existing experimental study and the numerical analysis. Based on the identified boundary condition, on assuming the condition of the actual driving, the temperature distribution in DPF was analyzed according to material properties of filter and the position of DPF.