2002
DOI: 10.1016/s0169-8095(02)00017-0
|View full text |Cite
|
Sign up to set email alerts
|

Electrical aerosol spectrometer of Tartu University

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
66
0
2

Year Published

2006
2006
2016
2016

Publication Types

Select...
6
4

Relationship

0
10

Authors

Journals

citations
Cited by 131 publications
(68 citation statements)
references
References 7 publications
0
66
0
2
Order By: Relevance
“…The FMPS is based on electrical aerosol spectrometer technology (Tammet et al, 2002) and measures particle concentration at a maximum rate of 1 Hz in 32 size bins with a manufacturer specified range of 6 to 560 nm electrical mobility diameter. The FMPS at 33 m was housed in a temperature-controlled enclosure, to reduce instrument variability due to temperature changes.…”
Section: Instrumentationmentioning
confidence: 99%
“…The FMPS is based on electrical aerosol spectrometer technology (Tammet et al, 2002) and measures particle concentration at a maximum rate of 1 Hz in 32 size bins with a manufacturer specified range of 6 to 560 nm electrical mobility diameter. The FMPS at 33 m was housed in a temperature-controlled enclosure, to reduce instrument variability due to temperature changes.…”
Section: Instrumentationmentioning
confidence: 99%
“…For example, the TSI Scanning Mobility Particle Spectrometers (SMPS) employed here which use a combination of an Electrostatic Classifier (EC) to control the sample flow and neutralize charge on the particles (from a beta source), a Differential Mobility Analyzer (DMA) for particle size selection before 571 being passed to a Condensation Particle Counter (CPC) for counting. (ii) Particle detection using multiple, low-noise electrometers (Tammet et al 2002). For example, the TSI Fast Mobility Particle Sizer (FMPS) employed here.…”
Section: Introductionmentioning
confidence: 99%
“…By recording the thermal energy absorbed from a light beam, either as an acoustic wave or incandescence, they are capable of high sensitivity and time resolution (Witze et al 2004), but solely to the black carbon component of exhaust PM. A more general capability for aerosol study is provided by the ELPI, which measures aerodynamic diameter, as well as the engine exhaust particle sizer (EEPS) and the differential mobility spectrometer (DMS500), which record electrical mobility diameter (both are similar to the electrical aerosol spectrometer (EAS; Tammet et al 1998). These instruments record timeresolved particle size distributions and are therefore capable of 69 indirectly providing PM mass.…”
Section: Introductionmentioning
confidence: 99%