Electrical strength of air containing ozone and nitric oxides produced by intensive partial discharges

Abstract: Internal arcing ter. results of gapped Sic arresters are presented. During a .-st in which the arrester is exposed to internal arcing, the positive impulse breakdown voltage increases. Measurements made with a model arrangement indicate that the increase in the electrical strength of gas is higher for positive than for negative impulse polarity. When the internal discharges extinguish, recovery processes occur. Additional phenomena that can cause changes in the electrical strength are discussed.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
6
0

Year Published

2004
2004
2018
2018

Publication Types

Select...
3
3

Relationship

0
6

Authors

Journals

citations
Cited by 11 publications
(7 citation statements)
references
References 6 publications
1
6
0
Order By: Relevance
“…Therefore in the initially dry arrester interior the production of moisture is possible [11]. This was confirmed by Chrzan [7] and Izumi [12] during varistor ageing by partial discharges. In their experiments small liquid droplets were found.…”
Section: Influence Of Partial Dischargessupporting
confidence: 59%
See 2 more Smart Citations
“…Therefore in the initially dry arrester interior the production of moisture is possible [11]. This was confirmed by Chrzan [7] and Izumi [12] during varistor ageing by partial discharges. In their experiments small liquid droplets were found.…”
Section: Influence Of Partial Dischargessupporting
confidence: 59%
“…Therefore, it can concentrate at the bottom of the arrester and cause degradation of the varistors and the sealing. Ozone is an electronegative gas, therefore the electrical strength of air containing this gas and other by-products of partial discharges is higher than that of pure air [7]. When partial discharges cease the electrical strength of the gas mixture decreases.…”
Section: Influence Of Partial Dischargesmentioning
confidence: 99%
See 1 more Smart Citation
“…The effect of partial discharges, environmental conditions like pollution and behaviour of surge arresters under steep front waves had been reported in the past . Darveniza et al studied zinc oxide arrester response to multi‐pulse lightning impulse currents.…”
Section: Introductionmentioning
confidence: 99%
“…Corona, surface and cavity are the three common PDs which occur frequently in many power apparatus [38,39,40]. The causes of their occurrences and the damages they pose to the machines and environment [41,42,43] are important considerations.…”
Section: Types Of Pdmentioning