1990
DOI: 10.1016/0168-3659(90)90165-p
|View full text |Cite
|
Sign up to set email alerts
|

Electrically controlled drug delivery system using polyelectrolyte gels

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
64
0

Year Published

1999
1999
2024
2024

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 127 publications
(65 citation statements)
references
References 14 publications
1
64
0
Order By: Relevance
“…In the case of calcium alginate gels, the Ca 2+ ions, which were used for cross-linking, and H 3 O + ions, which were generated in the alginate gels, moved toward the cathode, 26,27,30 and the water from the outside entered into the alginate gels. Therefore, the calcium alginate gel near the anode decreased in size, and the calcium alginate gel near the cathode increased in size.…”
Section: Evaluation Of the Stimulus Response S Obara Et Almentioning
confidence: 99%
“…In the case of calcium alginate gels, the Ca 2+ ions, which were used for cross-linking, and H 3 O + ions, which were generated in the alginate gels, moved toward the cathode, 26,27,30 and the water from the outside entered into the alginate gels. Therefore, the calcium alginate gel near the anode decreased in size, and the calcium alginate gel near the cathode increased in size.…”
Section: Evaluation Of the Stimulus Response S Obara Et Almentioning
confidence: 99%
“…An abrupt volumetric change is expected for this purpose because it is induced by such controllable parameters as temperature, pH, additives concentration, electrical field and so on (Ishihara et al, 1984;Hoffman et al, 1986;Bae et al, 1987;Sawahata et al, 1990;Dong and Hoffman, 1991;Baker and Siegel, 1996;Kaneko et al, 1997;Sahoo et al, 1998;Park, 1999;Ebara et al, 2001). For instance, Nisopropylacrylamide (NIPAAm)/butyl methacrylate (BMA) gel was used to control the release rate of indomethacin by the abrupt swelling/shrinkage induced by temperature changes (Bae et al, 1987).…”
Section: Introductionmentioning
confidence: 99%
“…As a result, hydrogel material facing the cathode displayed more prominent swelling than the side facing the anode. Another example is the use of Poly(acrylic acid) (PAA) hydrogel microsphere as a drug delivery system [89,90] . PAA hydrogel microspheres showed rapid and sharp shrinkage when electric field was applied, due to electroosmosis and electrophoresis.…”
Section: Electric Field Responsive Hydrogelmentioning
confidence: 99%