2017
DOI: 10.1111/jce.13147
|View full text |Cite
|
Sign up to set email alerts
|

Electrocardiographic Predictors of Long‐Term Cardiac Pacing Dependency Following Transcatheter Aortic Valve Implantation

Abstract: Increased pre- and postprocedural PR intervals and pre-existing RBBB are reliable predictors for long-term PPM dependency, while left bundle branch block or QRS width are misleading factors. Our study suggests that the decision for implanting PPM after TAVI should be based mostly on the prolongation of the PR interval.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
23
2

Year Published

2018
2018
2024
2024

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 42 publications
(25 citation statements)
references
References 34 publications
0
23
2
Order By: Relevance
“…We also demonstrated that the majority of patients implanted for paroxysmal CAVB (83%) had a significant VP percentage at the first pacemaker interrogation, suggesting the need for PPI in this clinical situation. Finally, one episode of transient CAVB seems Except for the initial conduction disorder, we did not find any predictive factors of pacemaker use contrary to Naveh et al 13 In this study, PR interval < 210 ms and PR interval increment of < 28 ms recorded during the immediate post-TAVI period had a high negative predictive value for long-term pacemaker dependency (respectively 93% and 95%). Akin et al also found that a PR interval longer than 200 ms post-TAVI was a predictive factor for the development of high degree AV block during follow-up.…”
Section: Discussioncontrasting
confidence: 87%
See 1 more Smart Citation
“…We also demonstrated that the majority of patients implanted for paroxysmal CAVB (83%) had a significant VP percentage at the first pacemaker interrogation, suggesting the need for PPI in this clinical situation. Finally, one episode of transient CAVB seems Except for the initial conduction disorder, we did not find any predictive factors of pacemaker use contrary to Naveh et al 13 In this study, PR interval < 210 ms and PR interval increment of < 28 ms recorded during the immediate post-TAVI period had a high negative predictive value for long-term pacemaker dependency (respectively 93% and 95%). Akin et al also found that a PR interval longer than 200 ms post-TAVI was a predictive factor for the development of high degree AV block during follow-up.…”
Section: Discussioncontrasting
confidence: 87%
“…Except for the initial conduction disorder, we did not find any predictive factors of pacemaker use contrary to Naveh et al . In this study, PR interval < 210 ms and PR interval increment of < 28 ms recorded during the immediate post‐TAVI period had a high negative predictive value for long‐term pacemaker dependency (respectively 93% and 95%).…”
Section: Discussionmentioning
confidence: 99%
“…Importantly, only new conduction abnormalities, those that had not been present prior to the procedure, were recorded. This study did not examine the effects of preexisting conduction abnormalities as others have done so in the past . Our study also did not focus on valve type as the long study period meant that several different models were used and this was not the emphasis of our research.…”
Section: Methodsmentioning
confidence: 99%
“…Baseline and post-procedural first degree AV Blocks (AVB) as well as a left anterior hemiblock have been studied as predictors of long term dependency on PPM, however have not qualified as independent predictors of advanced conduction abnormality post-TAVR (35). An implantation depth of less than 6 mm and newer designs that allow implantation higher in the LVOT also show a lower trend in conduction abnormalities and PPM implants (6,8,29).…”
Section: Predictors Of Ppm Implant Post Tavrmentioning