2019
DOI: 10.1002/elan.201900274
|View full text |Cite
|
Sign up to set email alerts
|

Electrochemical Aptasensor with Layer‐by‐layer Deposited Polyaniline for Aflatoxin M1 Voltammetric Determination

Abstract: Mycotoxins are highly toxic metabolites of some fungi that frequently contaminate water, food and feed and hence cause several human and animal diseases. In this work, a new approach to the fast and reliable determination of aflatoxin M1 (AFM1) in water and milk has been proposed with reagent free protocol of signal measurement. For this purpose, DNA aptamer selective to AFM1 was entrapped between two thin layers of polyaniline (PANI) electrodeposited on glassy carbon electrode. The incubation of the aptasenso… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 16 publications
(7 citation statements)
references
References 51 publications
0
7
0
Order By: Relevance
“…The surface charge resistance (Rct) is represented by the semicircle outlines, while the electron diffusion velocity is represented by lines. 61–65 The Mn 2 O 3 FL/C/GCE displayed a low semicircle and high line pathway. While the GCE and Mn 2 O 3 NLs/C/GCE showed a high semicircle and low line pathway.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The surface charge resistance (Rct) is represented by the semicircle outlines, while the electron diffusion velocity is represented by lines. 61–65 The Mn 2 O 3 FL/C/GCE displayed a low semicircle and high line pathway. While the GCE and Mn 2 O 3 NLs/C/GCE showed a high semicircle and low line pathway.…”
Section: Resultsmentioning
confidence: 99%
“…The EIS measurements are one of the tools that are used for outlining the electrochemical properties of the fabricated electrodes. 49,60–62 The EIS examination of GCE, Mn 2 O 3 NLs/C/GCE, and Mn 2 O 3 FL/C/GCE showed the surface resistance and electron diffusion pathways. Fig.…”
Section: Resultsmentioning
confidence: 99%
“…The equivalent circuit chosen ascribes the charge transfer conditions that take place on the electrode covered with a rather thick permeable layer so that two independent equillibria exist on the inner and outer interface of the modifying layer. Previously, the formation of two semicircles was observed in impedimetric biosensors utilizing bulky nonconductive but charged molecules like DNA [ 33 , 48 ] or antibodies [ 49 , 50 ], which are able to form differently charged areas in close proximity to the electrode interface. The specific form of the Nyquist diagrams and its relation to the heterogeneity of the surface layer and its properties is discussed in [ 51 , 52 ].…”
Section: Resultsmentioning
confidence: 99%
“…The aptamers commonly bear negative charge related to the phosphate residues of the backbone and hence they can be rather easily accumulated on positively charge carriers. For this purpose, some polyelectrolytes, such as poly(ethylene imine) (PEI) [103,104], poly(diallyldimethylammonium chloride) (PDDA) or polyaniline [105], are used as a kind of molecular "glue" combining oppositely charged components of the surface layer (e.g., carboxylated carbonaceous materials and aptamers). Electrostatic assembling is governed by the charge density and flexibility of the charge carriers and is also affected by small ions present in the solution as a supporting electrolyte.…”
Section: Aptamer Immobiizationmentioning
confidence: 99%
“…The above description does not exhaust the variety of the methods for monitoring aptamer-analyte interactions described in the aptasensors using carbon nanomaterials. Thus, the intrinsic redox activity of electroactive polymers such as polyaniline and polypyrrole changes with analyte binding due to variation of the charge distribution and counter ion access within the polymer layer [105]. In some cases, aptamer acts as a specific sorbent and accumulates analyte molecules for their following oxidation on electrode.…”
Section: Signal Measurement Modesmentioning
confidence: 99%