2009
DOI: 10.1016/j.ab.2008.11.006
|View full text |Cite
|
Sign up to set email alerts
|

Electrochemical assay of plasmin activity and its kinetic analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
30
0

Year Published

2010
2010
2023
2023

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 35 publications
(33 citation statements)
references
References 38 publications
3
30
0
Order By: Relevance
“…It is noteworthy that the k cat /K m values of legumain and cathepsin B are relatively low, but they have high biological significance respect to cancer diagnosis and treatment. The speed and required enzyme concentration in the electrochemical measurements can be significantly improved when this technique is used to detect other proteases with higher k cat /K m values, such as trypsin at (1.44 ± 0.1) × 10 6 M −1 s −1 , 15 α-thrombin at (1.0 ± 0.2) × 10 6 M −1 s −1 , 15 and plasmin at 6.7 × 10 5 M −1 s −1 16. …”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…It is noteworthy that the k cat /K m values of legumain and cathepsin B are relatively low, but they have high biological significance respect to cancer diagnosis and treatment. The speed and required enzyme concentration in the electrochemical measurements can be significantly improved when this technique is used to detect other proteases with higher k cat /K m values, such as trypsin at (1.44 ± 0.1) × 10 6 M −1 s −1 , 15 α-thrombin at (1.0 ± 0.2) × 10 6 M −1 s −1 , 15 and plasmin at 6.7 × 10 5 M −1 s −1 16. …”
Section: Resultsmentioning
confidence: 99%
“…In previous electrochemical detection of proteases including trypsin, 15 a-thrombin, 15 and plasmin, 16 normal CV measurements on gold electrodes were used. This method was found not applicable on carbon electrode.…”
Section: Resultsmentioning
confidence: 99%
“…After incubation of different amounts of plasmin in FcPS‐immobilized electrode solution a significant decrease in current was noted. The kinetic parameters were found to be 10 times smaller than those of the homogeneous system, which might be documented to decrease in association rate constant of the fixed substrate on the surface and plasmin …”
Section: Non‐biological Applicationsmentioning
confidence: 85%
“…Following this, more electrochemical techniques have been employed to measure proteolysis of Fc-labeled peptides immobilized on macroscopic gold electrodes. The enzymatic properties of proteases including trypsin, thrombin and plasmin have been quantitatively analyzed with the kinetic Fc signal after adding the proteases (Adjemian et al, 2010; Ohtsuka et al, 2009). However, electrochemical detection and quantitative analyses of protease activities in more complicated samples such as whole tissue lysates have not been reported.…”
Section: Introductionmentioning
confidence: 99%