2007
DOI: 10.1007/s00604-007-0881-1
|View full text |Cite
|
Sign up to set email alerts
|

Electrochemical behavior of lead(II) at poly(phenol red) modified glassy carbon electrode, and its trace determination by differential pulse anodic stripping voltammetry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
16
0

Year Published

2011
2011
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 33 publications
(16 citation statements)
references
References 27 publications
0
16
0
Order By: Relevance
“…The linear regression equation was: I pa ¼ 12:4107C À 0:9342 (I pa , the anodic peak current, μA; C, the concentration of the Pb 2+ , nM), with a correlation coefficient of 0.999. The amperometric response to Pb(II) is linear in the range from 0.10 to 44 nM, and the detection limit is 0.04 nM, which was lower than that of other modified electrodes [7,10,39,40] (Table 1).…”
Section: Amperometric Response To Lead Ionmentioning
confidence: 89%
“…The linear regression equation was: I pa ¼ 12:4107C À 0:9342 (I pa , the anodic peak current, μA; C, the concentration of the Pb 2+ , nM), with a correlation coefficient of 0.999. The amperometric response to Pb(II) is linear in the range from 0.10 to 44 nM, and the detection limit is 0.04 nM, which was lower than that of other modified electrodes [7,10,39,40] (Table 1).…”
Section: Amperometric Response To Lead Ionmentioning
confidence: 89%
“…The sensitivity is not lower than that of complicated modified electrode 4,10,11,14,[29][30][31] or graphiteepoxy composite electrode. 9 Therefore, it is an attractive and very promising option for ultratrace metals analysis in seawater with two great advantages: the avoidance of harmful mercury and the avoidance of time-consuming procedures for pretreating water samples.…”
Section: Discussionmentioning
confidence: 99%
“…Though the sensitivity of the conventional disk glassy carbon electrode (GCE) isn't satisfactory towards the monitoring of trace amount of heavy metals, some methods based on modified GCEs have been studied by far. 4,[11][12][13][14] To the best of our knowledge, there isn't report on the performance of determining lead using a GCE with large electrochemical area, though the stability and reproducibility of a GCE are obvious better than a modified electrode. This paper aimed to give a first-time report on the electrochemical determination of Pb 2+ in artifical seawater and real seawater by utilizing a novel columnar glassy carbon electrode (CGCE), which has a prodigious active area, allowing for an attractive high sensitivity by differential pulse stripping voltammetry (DPSV) technique.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…e modified electrode with increased surface is due to the presence of ZIF-8. e larger effective surface area results in more active sites and leads to a higher signal-to-nose ratio [42].…”
Section: Effects Of Scanmentioning
confidence: 99%