Electrochemical characterization of nanosurface-modified screen-printed electrodes by using a source measure unit

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
3
1
1

Relationship

1
4

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 21 publications
0
4
0
Order By: Relevance
“…7D) demonstrate that the electrodes consistently exhibit similar peak current values, peak positions, and surface area. The observed variation within the same batch electrodes was less than 1.80%, whereas the inter-batch variability was approximately 2.87%.where i p is the current peak in amps, n is the number of electrons transferred in the electrochemical event ( n = 1), F is Faraday constant in C mol −1 , A is the electrode area in cm 2 , D is the diffusion coefficient ( D = 6.40 × 10 6 cm 2 s −1 ), C is the electrolyte concentration in mol cm 3 , υ is the scan rate in V s −1 , R is gas constant in J K −1 mol −1 , and T is the temperature in K. 65,66…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…7D) demonstrate that the electrodes consistently exhibit similar peak current values, peak positions, and surface area. The observed variation within the same batch electrodes was less than 1.80%, whereas the inter-batch variability was approximately 2.87%.where i p is the current peak in amps, n is the number of electrons transferred in the electrochemical event ( n = 1), F is Faraday constant in C mol −1 , A is the electrode area in cm 2 , D is the diffusion coefficient ( D = 6.40 × 10 6 cm 2 s −1 ), C is the electrolyte concentration in mol cm 3 , υ is the scan rate in V s −1 , R is gas constant in J K −1 mol −1 , and T is the temperature in K. 65,66…”
Section: Resultsmentioning
confidence: 99%
“…where i p is the current peak in amps, n is the number of electrons transferred in the electrochemical event (n = 1), F is Faraday constant in C mol −1 , A is the electrode area in cm 2 , D is the diffusion coefficient (D = 6.40 × 10 6 cm 2 s −1 ), C is the electrolyte concentration in mol cm 3 , υ is the scan rate in V s −1 , R is gas constant in J K −1 mol −1 , and T is the temperature in K. 65,66…”
Section: Electrode Characterizationmentioning
confidence: 99%
“…4(E), confirming once again that peak current increases linearly with applied scan rates, which strongly indicates the diffusion-controlled redox process, making it an effective material for battery-type electrodes. 59–61…”
Section: Resultsmentioning
confidence: 99%
“…4(E), conrming once again that peak current increases linearly with applied scan rates, which strongly indicates the diffusion-controlled redox process, making it an effective material for battery-type electrodes. [59][60][61] As shown in Fig. 4(F), the capacity storage characteristics of all the NiCo LDH samples were also examined by GCD at different current densities ranging from 2.5 to 20 mA cm −2 .…”
Section: Resultsmentioning
confidence: 99%