2008
DOI: 10.1016/j.aca.2008.07.050
|View full text |Cite
|
Sign up to set email alerts
|

Electrochemical detection of celecoxib at a polyaniline grafted multiwall carbon nanotubes modified electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
14
0

Year Published

2010
2010
2013
2013

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 37 publications
(15 citation statements)
references
References 33 publications
1
14
0
Order By: Relevance
“…Also, the proposed method was compared with voltammetric methods, too. 4,34 The results confirm that the modified electrode retained its efficiency for the determination of CEL in pharmaceutical as well as serum samples for months without any significant divergence in its response.…”
Section: Effect Of the Scan Ratesupporting
confidence: 65%
See 1 more Smart Citation
“…Also, the proposed method was compared with voltammetric methods, too. 4,34 The results confirm that the modified electrode retained its efficiency for the determination of CEL in pharmaceutical as well as serum samples for months without any significant divergence in its response.…”
Section: Effect Of the Scan Ratesupporting
confidence: 65%
“…In Table 3 the linear calibration range, limit of detection and real sample of several previously published methods 34,36 are compared with those of the proposed AuNPs/GR-CILE electrochemical sensor for the determination of CEL. The proposed electrochemical sensor possesses a short response time, low cost, and could be used for months without any significant divergence in its response in a real sample.…”
Section: Comparison Of the Sensitivity Of Aunps/gr-cile With That Of mentioning
confidence: 99%
“…3 For the fabrication of electrochemical biosensor, CNTs have been used as an electrode modifying material on the surface of platinum, 4 glassy carbon, 5 graphite, 6 and gold, 7 electrodes. CNT modified electrodes have been shown to possess improved sensitivity and selectivity toward the determination of many biomolecules, including cytochrome-c, 8 dihydronicotinamide adenine dinucleotide, 9 glucose, 10 H 2 O 2 11 and ascorbic acid. 12 Alternatively, CNTs/conducting polymers (CPs) composites have received significant interest due to the coating of positively charged CP onto MWNT can lead to new composite materials possessing the properties of each component with a synergistic effect that would be useful in particular applications.…”
Section: Introductionmentioning
confidence: 99%
“…As one of the most significant conducting polymers, polyaniline (PANI) has been used for the fabrication of electrochemical biosensors due to its good conductivity and electrochemical activity [11][12][13]. During the fabrication of electrochemical biosensors, PANI is commonly synthesized by electropolymerization of aniline on the surface of electrodes and biomolecules are added into the monomer solution for subsequent entrapment.…”
Section: Introductionmentioning
confidence: 99%