2021
DOI: 10.1016/j.aca.2021.339124
|View full text |Cite
|
Sign up to set email alerts
|

Electrochemical detection of dopamine with negligible interference from ascorbic and uric acid by means of reduced graphene oxide and metals-NPs based electrodes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
17
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 63 publications
(19 citation statements)
references
References 89 publications
0
17
0
Order By: Relevance
“…In Figure 7D, the spectrum of rGO only is reported for comparison. In the Raman spectrum of rGO two main peaks at about 1350 and 1600 cm −1 , corresponding to the D and G band [118], respectively, can be observed. These peaks were found also in the rGO-ZnO-NRs electrode confirming the deposition of rGO.…”
Section: Resultsmentioning
confidence: 96%
“…In Figure 7D, the spectrum of rGO only is reported for comparison. In the Raman spectrum of rGO two main peaks at about 1350 and 1600 cm −1 , corresponding to the D and G band [118], respectively, can be observed. These peaks were found also in the rGO-ZnO-NRs electrode confirming the deposition of rGO.…”
Section: Resultsmentioning
confidence: 96%
“…As presented in Figure 10 a, there was about a 20% enhanced peak current response on GOQD over respective control SPCE, which may be due to negative charge carried with GOQD and enhanced electronic conductivity effects. Next, simultaneous electrochemical determination of uric acid (UA) and ascorbic acid (AA) were chosen as a model compound due to their importance in a biological system [ 45 , 46 ]. In general, owing to their closer electrochemical oxidation potentials, an overlapped electrochemical oxidation signal was observed while analyzing these compounds.…”
Section: Resultsmentioning
confidence: 99%
“…UA produce a minimal response, and its outcome was insignificant. Patella et al [32] also reported a minor reaction for UA The amperometry approach (differential pulsed) constantly reacted, with a steady applied voltage, rising into the current with subsequent of 4 µM DA in the PBS electrolytic media, as illustrated in Figure 6b. With the addition of AA and UA under the optimized testing conditions as potentially interfering components, the AgNPs-2ADPA incorporated electrode showed good non-participation of AA and UA.…”
Section: Study Utilizing the Agnps-2adpa Doped Electrodementioning
confidence: 92%
“…UA produce a minimal response, and its outcome was insignificant. Patella et al [32] also reported a minor reaction for UA and AA in the DPV analyses since they produced around 12-and 6% responses. AgNPs-2ADPA was capable of enhancing the catalytic performance of DA.…”
Section: Study Utilizing the Agnps-2adpa Doped Electrodementioning
confidence: 94%