Abstract: Phenylethanolamine A (PEA), a β-agonist, was found to be illegally used as a growth promoter in pigs last year, causing Chinese government's great attention. Here, a sensitive electrochemical method was developed for detecting PEA by immobilization of gold nanoparticles (AuNPs), multiwalled carbon nanotubes (MWCNTs) and Nafion on the surface of a glassy carbon electrode (GCE). The Nafion/MWCNTs/AuNPs film was characterized by scanning electronic micrographs (SEM) and electrochemical impedance spectroscopy (EIS… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
8
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(8 citation statements)
references
References 23 publications
0
8
0
Order By: Relevance
“…In the linear equation, I 0 stands for the ECL intensity for 0 ng mL À1 PA, while I stands for the ECL intensity of different concentrations of PA. Compared to the previous literature for detecting PA, [14][15][16][17] this study has a wider linear range and a lower LOD, suggesting that this immunosensor displays a more simple and convenient prospect of application.…”
Section: Ecl Detection Of Pamentioning
confidence: 76%
See 1 more Smart Citation
“…In the linear equation, I 0 stands for the ECL intensity for 0 ng mL À1 PA, while I stands for the ECL intensity of different concentrations of PA. Compared to the previous literature for detecting PA, [14][15][16][17] this study has a wider linear range and a lower LOD, suggesting that this immunosensor displays a more simple and convenient prospect of application.…”
Section: Ecl Detection Of Pamentioning
confidence: 76%
“…12,13 To the best of our knowledge, few analytical methods have been reported to monitor PA except three studies with LC-MS/MS, 14 ELISA, 15 immunoaffinity chromatography columns 16 and electrochemical methods. 17 In 2010, the Ministry of Agriculture of China issued a standard for the detection of PA in feed using high-performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS). 5 Chromatographic tandem mass spectrometry methods are frequently applied in conrmation with preciseness.…”
Section: Introductionmentioning
confidence: 99%
“…As shown in Table 1, the results of RGO-PIL sensor were compared with that of other published methods detecting b-agonists. [47][48][49][50][51][52][53] The results demonstrated wide linear range and low LOD of the prepared RGO-PIL sensor for PEA.…”
Section: Electrochemical Sensing Of Peamentioning
confidence: 99%
“…Immunoassays are analytical methods which are based on the specific interaction between an antibody and corresponding antigen. Other techniques including electrochemical sensors, electrochemiluminescence immunosensors, immunochromatographic assay (ICA) and surface‐enhanced Raman scattering based immunochromatographic assay (SERS‐ICA) were also developed for the detection of PA, but these methods exhibited the disadvantages of time‐consuming performance or low sensitivity and could not meet the requirements of rapid, on‐site and high throughput detection. Therefore, there is an urgent need to develop high sensitive and specific, low‐cost, rapid, on‐site and high throughput analytical method for the detection of PA.…”
Section: Introductionmentioning
confidence: 99%