2022
DOI: 10.3390/molecules27144578
|View full text |Cite
|
Sign up to set email alerts
|

Electrochemical Immunoassay for Tumor Marker CA19-9 Detection Based on Self-Assembled Monolayer

Abstract: A CA19-9 electrochemical immunosensor was constructed using a hybrid self-assembled membrane modified with a gold electrode and applied to detect real samples. Hybrid self-assembled membranes were selected for electrode modification and used to detect antigens. First, the pretreated working electrodes were placed in a 3-mercaptopropionic acid (MPA)/β-mercaptoethanol (ME) mixture for 24 h for self-assembly. The electrodes were then placed in an EDC/NHS mixture for 1 h. Layer modification was performed by stepwi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(2 citation statements)
references
References 36 publications
0
2
0
Order By: Relevance
“…Wei et al developed an electrochemical immunosensor for the sensitive detection of CA19-9 using a hybrid self-assembled membrane modified with a gold electrode. The immunosensor responded to CA19-9 in a linear range of 0.05–500 U/mL with a lower detection limit of 0.01 U/mL [ 139 ]. This sensor was used for a real-sample analysis with a standard deviation of less than 5%.…”
Section: Biomarkers and Their Biosensorsmentioning
confidence: 99%
“…Wei et al developed an electrochemical immunosensor for the sensitive detection of CA19-9 using a hybrid self-assembled membrane modified with a gold electrode. The immunosensor responded to CA19-9 in a linear range of 0.05–500 U/mL with a lower detection limit of 0.01 U/mL [ 139 ]. This sensor was used for a real-sample analysis with a standard deviation of less than 5%.…”
Section: Biomarkers and Their Biosensorsmentioning
confidence: 99%
“…Then, CA 19-9 antibodies were immobilized onto the modified electrode using EDC/NHS chemistry which activated the carboxylic acid groups on the surface of MWCNTs for CA 19-9 antigen detection. Recently, Wei et al [60] described another label-free EC immunosensing method for the detection of CA 199 using piranha pretreated gold electrode. The pretreated electrode was coated with a self-assembled layer of 3-mercaptopropionic acid (MPA) and β-mercaptoethanol (ME) hybrid (MPA/ME/Au).…”
Section: Label-free Ec Immunosensors For Oc Biomarkers Detectionmentioning
confidence: 99%