2019
DOI: 10.1016/j.bios.2019.111580
|View full text |Cite
|
Sign up to set email alerts
|

Electrochemical immunosensor based on MoS2 NFs/Au@AgPt YNCs as signal amplification label for sensitive detection of CEA

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
26
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 81 publications
(26 citation statements)
references
References 41 publications
0
26
0
Order By: Relevance
“…The biosensor had a range of linearity from 1 pg/mL to 50 ng/mL and a limit of detection of 0.27 pg/mL. Analogously, Ma et al [ 93 ] also synthesized a sandwich-type electrochemical immunosensor with a broader detecting range (10 fg/mL to 100 ng/mL) and a lower limit of detection (3.09 fg/mL). The trimetallic yolk-shell Au@AgPt nanocubes (Au@AgPt YNCs) with good catalytic activity loaded on amino-modified MoS 2 nanoflowers to form MoS 2 NFs/Au@AgPt YNCs as the marker of Ab 2 , which could catalyze the reduction of H 2 O 2 more effectively and thus amplify the current signal.…”
Section: Biosensorsmentioning
confidence: 99%
“…The biosensor had a range of linearity from 1 pg/mL to 50 ng/mL and a limit of detection of 0.27 pg/mL. Analogously, Ma et al [ 93 ] also synthesized a sandwich-type electrochemical immunosensor with a broader detecting range (10 fg/mL to 100 ng/mL) and a lower limit of detection (3.09 fg/mL). The trimetallic yolk-shell Au@AgPt nanocubes (Au@AgPt YNCs) with good catalytic activity loaded on amino-modified MoS 2 nanoflowers to form MoS 2 NFs/Au@AgPt YNCs as the marker of Ab 2 , which could catalyze the reduction of H 2 O 2 more effectively and thus amplify the current signal.…”
Section: Biosensorsmentioning
confidence: 99%
“…Therefore, the sensor got a low detection limit of 26 fg mL −1 with the help of signal probe amplification. Other MoS 2 -based electrochemical nanoprobes were also used to detect cardiac troponin I, HBsAg, and CEA due to their outstanding signal amplification effect, respectively [ 49 , 50 , 74 ].…”
Section: Mos 2 -Based Nanoprobes For Sensing Appli...mentioning
confidence: 99%
“…The biosensor showed a sensitivity of 13.80 µA mM −1 cm −2 . The developed bio-catalytic interface based on two-dimensional MoS 2 and gold nanoparticles has the potential to be used for the immobilization of other biomolecules [49][50][51][52].…”
Section: Gold Nanostructures and Their Use In Hybrid Glucose Biosensorsmentioning
confidence: 99%