2015
DOI: 10.1016/j.bios.2015.02.039
|View full text |Cite
|
Sign up to set email alerts
|

Electrochemical immunosensor for botulinum neurotoxin type-E using covalently ordered graphene nanosheets modified electrodes and gold nanoparticles-enzyme conjugate

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
41
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
5
4

Relationship

1
8

Authors

Journals

citations
Cited by 76 publications
(41 citation statements)
references
References 58 publications
0
41
0
Order By: Relevance
“…Foods are easily contaminated by Clostridium botulinum during processing. Various (impedimetric, voltammetric and amperometric) electrochemical biosensors have been fabricated for BoNT detection [73][74][75][76]. In particular, electrochemical biosensors can achieve detection of this toxin in a fast and meticulous way, and they also provide a robust and cost-effective approach for real-time monitoring of BoNTs.…”
Section: Botulinum Neurotoxinsmentioning
confidence: 99%
See 1 more Smart Citation
“…Foods are easily contaminated by Clostridium botulinum during processing. Various (impedimetric, voltammetric and amperometric) electrochemical biosensors have been fabricated for BoNT detection [73][74][75][76]. In particular, electrochemical biosensors can achieve detection of this toxin in a fast and meticulous way, and they also provide a robust and cost-effective approach for real-time monitoring of BoNTs.…”
Section: Botulinum Neurotoxinsmentioning
confidence: 99%
“…Recently, 2D nanomaterial-based electrochemical biosensors have been applied to sensitively detect BoNTs in various samples including foods. For instance, Narayanan et al constructed an electrochemical immunosensor of the BoNT serotype E (BoNT/E) by using graphene nanosheets-aryldiazonium salts as transducers [74]. The as-proposed immunosensor shows a low limit of detection (LOD, 5 pg mL −1 ) and can be employed for rapid detection of BoNT/E with a total analysis time of 65 min.…”
Section: Botulinum Neurotoxinsmentioning
confidence: 99%
“…Narayanan et al [115] strongly modified graphene on the surface of a glassy carbon electrode by a series of covalent reactions, and an antibody was further modified on the graphene using the EDC/NHS cross-linking reagent. Using RaMIgG-ALP/AuNPs as a signal amplification marker, the detection of botulinum neurotoxin E was achieved through sandwich immunization with the detection range and detection limit achieving to 10 pg·mL −1 –10 ng·mL −1 and 5.0 pg·mL −1 , respectively.…”
Section: Electrochemical Immunosensors Based On Various Nanomaterialsmentioning
confidence: 99%
“…This method is very sensitive and specific, but this assay require a huge number of animals. Hence, it is necessary to replace the mouse bioassay with similarly sensitive another assays [16][17][18] .…”
Section: Introductionmentioning
confidence: 99%