2012
DOI: 10.1149/2.014211jes
|View full text |Cite
|
Sign up to set email alerts
|

Electrochemical Impedance Spectroscopy (EIS) Analysis of BTA Removal by TMAH during Post Cu CMP Cleaning Process

Abstract: An ex situ electrochemical impedance spectroscopy (EIS) method is used to evaluate the effectiveness of tetramethyl ammonium hydroxide (TMAH) in removing benzotriazole (BTA) layer from Cu surface after chemical mechanical polishing (CMP). Since the in situ EIS measurements could not be applied to characterize the cleaning process, ex situ EIS measurement is used in the present work. The impedance data are modeled by electrical equivalent circuit (EEC) analysis and the polarization resistance values are calcula… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
21
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 32 publications
(23 citation statements)
references
References 24 publications
0
21
0
Order By: Relevance
“…168,170 The use of a TMAH-based solution for removing BTA from the Cu surface is suggested in the literature. 168,[171][172][173] Less corrosion of Cu in TMAH solution than in NH 4 OH solution even at higher pH is reported in the literature. 172 Electrochemical impedance spectroscopy (EIS) analysis of Cu post-CMP is studied in the literature.…”
Section: Application-based Post-cmp Cleaningmentioning
confidence: 91%
See 2 more Smart Citations
“…168,170 The use of a TMAH-based solution for removing BTA from the Cu surface is suggested in the literature. 168,[171][172][173] Less corrosion of Cu in TMAH solution than in NH 4 OH solution even at higher pH is reported in the literature. 172 Electrochemical impedance spectroscopy (EIS) analysis of Cu post-CMP is studied in the literature.…”
Section: Application-based Post-cmp Cleaningmentioning
confidence: 91%
“…172 Electrochemical impedance spectroscopy (EIS) analysis of Cu post-CMP is studied in the literature. [173][174][175] EIS investigation revealed that the minimum concentration of 0.5 wt% TMAH is sufficient to remove BTA from the Cu surface. 173 However, TMAH is a harmful chemical for human health and the environment.…”
Section: Application-based Post-cmp Cleaningmentioning
confidence: 99%
See 1 more Smart Citation
“…43,44 Since surface passivation is an indicator of post-CMP residual adsorbates (like corrosion inhibitors), the efficiency of a PCMPC process can be checked by comparing i corr , LPR and/or A.C. impedance data recorded before and after surface cleaning. 45 Inclusion of microscopic scrutiny can additionally complement these findings. 46,47 …”
Section: Trends and Current Statusmentioning
confidence: 99%
“…43,44 Since surface passivation is an indicator of post-CMP residual adsorbates (like corrosion inhibitors), the efficiency of a PCMPC process can be checked by comparing i corr , LPR and/or A.C. impedance data recorded before and after surface cleaning. 45 Inclusion of microscopic scrutiny can additionally complement these findings. 46,47 New Challenges and Future Directions Further narrowing of process windows and new considerations of defect control are likely to add more CMP challenges for the ≤ 10 nm node integration.…”
Section: P211mentioning
confidence: 99%