2019
DOI: 10.37358/rc.19.4.7081
|View full text |Cite
|
Sign up to set email alerts
|

Electrochemical in vitro Properties of 316L Stainless Steel for Orthodontic Applications

Abstract: 316L Stainless steels are widely used in biomedical applications with respect to their excellent corrosion resistance, nonmagnetic properties, high ductility and acceptable biocompatibility. There have been made electrochemical studies in-vitro in order to determine the corrosion reactions, which are necessary for foreseeing the behavior of the materials used in orthodontic applications. The degradation of metals and alloys in the human body is a combination of effects due to corrosion and mechanical activitie… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
2

Relationship

2
5

Authors

Journals

citations
Cited by 10 publications
(8 citation statements)
references
References 12 publications
(19 reference statements)
0
8
0
Order By: Relevance
“…A three electrode cell was used and consists of: as working electrode (WE) the 304 L stainless steel sample with active area of 3.5 cm 2 , an Ag/AgCl (saturated solution of KCl) as reference electrode (RE) and a Pt-Rh grid as the counter electrode (CE). Two types of simulated body fluids were selected, namely Hank's solution (pH = 7.25) and Fusayama Meyer artificial saliva (pH=4.8) [15], Citric acid pH= 1.81) was also selected for corrosion study of 304L stainless steel because it is found in citrus juice, apples, tobacco leaf, wine, etc. and can affect the composition and change the pH of the mouth cavity.…”
Section: Electrochemical Cell and Solution Compositionmentioning
confidence: 99%
“…A three electrode cell was used and consists of: as working electrode (WE) the 304 L stainless steel sample with active area of 3.5 cm 2 , an Ag/AgCl (saturated solution of KCl) as reference electrode (RE) and a Pt-Rh grid as the counter electrode (CE). Two types of simulated body fluids were selected, namely Hank's solution (pH = 7.25) and Fusayama Meyer artificial saliva (pH=4.8) [15], Citric acid pH= 1.81) was also selected for corrosion study of 304L stainless steel because it is found in citrus juice, apples, tobacco leaf, wine, etc. and can affect the composition and change the pH of the mouth cavity.…”
Section: Electrochemical Cell and Solution Compositionmentioning
confidence: 99%
“…From the linear polarization diagram, quantitative information on the polarization resistance and corrosion currents can be extracted from the curve slope according to the Stern-Geary equation [5].…”
Section: Linear Polarization (Lp)mentioning
confidence: 99%
“…They can be used with equal success in the food [1], pharmaceutical industries [2] or dental medicine [3]. However, in recent years, interest in AISI 316L (316L-SS) has increased from economic considerations (low cost, reasonable strength, corrosion resistance and biocompatibility) [4][5]. For example, in dentistry, it is used in a variety of applications (endodontic files in root canal therapy, sterilized instruments, metal posts in root canal treated teeth, arch wires, temporary crowns and brackets in orthodontics) [5].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…It is concluded that the corrosion resistance is high when pH is low (acidic condition) and chloride ion concentration is less. 8 It has been concluded that snakefruit seeds extract controlled the release of chromium and nickel ion from stainless steel orthodontic wire in saliva.…”
Section: Introductionmentioning
confidence: 99%