2013
DOI: 10.1002/elan.201300048
|View full text |Cite
|
Sign up to set email alerts
|

Electrochemical Investigations of the Anticancer Drug Idarubicin Using Multiwalled Carbon Nanotubes Modified Glassy Carbon and Pyrolytic Graphite Electrodes

Abstract: The effect of surface modifications on the electrochemical behavior of the anticancer drug idarubicin was studied at multiwalled carbon nanotubes modified glassy carbon and edge plane pyrolytic graphite electrodes. The surface morphology of the modified electrodes was characterized by scanning electron microscopy. The modified electrodes were constructed for the determination of idarubicin using adsorptive stripping differential pulse voltammetry. The experimental parameters such as supporting electrolyte, pH,… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
14
0

Year Published

2013
2013
2020
2020

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 31 publications
(14 citation statements)
references
References 42 publications
0
14
0
Order By: Relevance
“…Various carbon materials were implemented in aminated dendrimer coating with determination down to 0.13 µM of doxorubicin [48]. Modification of GCE with carbon nanotubes resulted in detection of 20-500 nM of daunorubicin [49] and 18.7 nM idarubicin [50]. In most cases described, the stage of preaccumulation is required and no specific interactions with DNA are used.…”
Section: "Here Fig 5"mentioning
confidence: 99%
“…Various carbon materials were implemented in aminated dendrimer coating with determination down to 0.13 µM of doxorubicin [48]. Modification of GCE with carbon nanotubes resulted in detection of 20-500 nM of daunorubicin [49] and 18.7 nM idarubicin [50]. In most cases described, the stage of preaccumulation is required and no specific interactions with DNA are used.…”
Section: "Here Fig 5"mentioning
confidence: 99%
“…There is no need for derivatization or time-consuming extraction steps in comparison with other techniques because electroanalytical methods are less sensitive to the matrix effects [28][29][30][31][32][33][34][35][36][37][38][39][40][41][42][43][44][45]. There is no need for derivatization or time-consuming extraction steps in comparison with other techniques because electroanalytical methods are less sensitive to the matrix effects [28][29][30][31][32][33][34][35][36][37][38][39][40][41][42][43][44][45].…”
Section: Introductionmentioning
confidence: 99%
“…Although, there are many reports about the simultaneous determination of dopamine and uric acid using electron transfer mediators [29][30][31][32][33][34], but in this study, we report the preparation and application of a CdTe quantum dots-modified carbon paste electrodes for the simultaneous determination of dopamine and uric acid without any additional modification such as addition of electron transfer mediator or specific reagents for the first time. Although, there are many reports about the simultaneous determination of dopamine and uric acid using electron transfer mediators [29][30][31][32][33][34], but in this study, we report the preparation and application of a CdTe quantum dots-modified carbon paste electrodes for the simultaneous determination of dopamine and uric acid without any additional modification such as addition of electron transfer mediator or specific reagents for the first time.…”
Section: Introductionmentioning
confidence: 99%
“…The analyte was first accumulated from acetate buffer solution, pH 4.5, and then the electrode is transferred in another buffer solution and differential pulse voltammogram is recorded. In similar conditions, the LOD of idarubicin was found to be 18.7 nM [47]. The use of GCE modified with carbon nanotubes and silver nanoparticles made it possible to detect 1.7 nM of doxorubicin [44].…”
Section: Anthracycline Drugs Detectionmentioning
confidence: 94%