2001
DOI: 10.1007/s002160100707
|View full text |Cite
|
Sign up to set email alerts
|

Electrochemical methods for monitoring of environmental carcinogens

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
31
0
3

Year Published

2002
2002
2017
2017

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 54 publications
(35 citation statements)
references
References 3 publications
1
31
0
3
Order By: Relevance
“…Percentage recovery in the range 99.06% to 99.77% , is quite good. Although lower detection limits and linear range of concentrations are available for estimation of some of the aromatic amines by using other reported methods involving/ not involving periodate oxidations [1][2][3][4][5][6][7] , all of these methods require lengthy preconcentration and pretreatment of the samples including many complex reactions of the sample with oxidants and chromogenic substances. Further, most of these methods require not-readily available facilities like GC-ECD, GC-MS, solid phase extraction coupled with HPLC, differential pulse voltammetry and adsorptive stripping voltammetry, flow injection method etc.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Percentage recovery in the range 99.06% to 99.77% , is quite good. Although lower detection limits and linear range of concentrations are available for estimation of some of the aromatic amines by using other reported methods involving/ not involving periodate oxidations [1][2][3][4][5][6][7] , all of these methods require lengthy preconcentration and pretreatment of the samples including many complex reactions of the sample with oxidants and chromogenic substances. Further, most of these methods require not-readily available facilities like GC-ECD, GC-MS, solid phase extraction coupled with HPLC, differential pulse voltammetry and adsorptive stripping voltammetry, flow injection method etc.…”
Section: Resultsmentioning
confidence: 99%
“…[1][2][3][4][5][6][7][8][9][10] There is one report available in literature regarding the kinetic-spectrophotometric estimation of some anilines based on their oxidation by periodate ion in aqueous/ mixed media. 11 Earlier reports have proposed the formation of binary or ternary complex formation as an intermediate respectively, in the reaction between aromatic amines and periodate ion either under uncatalysed [12][13][14][15][16][17][18][19][20][21][22][23][24][25][26] or Mn II catalysed conditions.…”
Section: Introductionmentioning
confidence: 99%
“…Açık havada katı halden gaz haline geçtiğinden haşere ile mücadelede ve güveleri [12][13]. Voltametrik tekniklerin üstün yanı; eser miktardaki metallerin, organik ve inorganik maddelerin analiz edilmesi, elektroaktif türlere karşı seçiciliğe sahip olması, geniş bir doğrusal çalışma aralığına izin vermesi, hızlı, taşınabilir ve düşük maliyetli analiz yapılabilmesidir [14][15][16].…”
Section: Introductionunclassified
“…Son yıllarda yeni elektrot şekli ve tasarımı (modifiye elektrotlar), elektrot aktivasyon işlemleri ve modern teknikler (puls-dalga formları, adsorptif teknikler, sıyırma) kullanılarak gerçekleştirilen ''katı elektrot voltametrisi'' sayesinde pikomolar altı derişim düzeylerinde çalışmaya olanak vermesinden dolayı voltametrik teknikler üstün özelliklere sahip olmuşlardır [16].…”
Section: Introductionunclassified
“…For certain, admittedly not too frequent cases, modern polarographic and voltammetric techniques are really the best method and quite frequently they are among the ™fit for the purpose methods∫. The polarographic and voltammetric methods developed in our UNESCO Laboratory of Environmental Electrochemistry for the determination of sub micro and subnanomolar concentrations of selected chemical carcinogens [41], nitrated pesticides or growth stimulators [42] and dyes [43] can serve as example.…”
mentioning
confidence: 99%