Electrochemical performance study of Ag/AgCl and Au flexible electrodes for unobtrusive monitoring of human biopotentials

Abstract: Flexible and stretchable electronics are a logical choice for the recording of biopotentials, due to their improved patient comfort and customizability. There is, however, significant variance in the signal quality received from these electrodes based on material, size, and target recording frequency. Here we develop a methodology based on Electrochemical Impedance Spectroscopy (EIS) and circuit modeling for optimizing electrodes for a specific application. We use EIS to measure the frequency dependent impedan… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
18
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
3
3

Relationship

5
1

Authors

Journals

citations
Cited by 9 publications
(18 citation statements)
references
References 24 publications
0
18
0
Order By: Relevance
“…Moreover, in addition to the observed group effect on neural firing (both during CPT and timed respiratory challenge), there was a significant group effect (CPTd vs. CPTi) on heart rate during the timed respiratory challenge (Supplemental Figure 1a). In the presented electrode device, both the electrode size and associated impedance, as well as the electrode shape and its arrangement on specific patterns can be customized 31 . This versatile electrode shaping can aid in neural structure source identification.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Moreover, in addition to the observed group effect on neural firing (both during CPT and timed respiratory challenge), there was a significant group effect (CPTd vs. CPTi) on heart rate during the timed respiratory challenge (Supplemental Figure 1a). In the presented electrode device, both the electrode size and associated impedance, as well as the electrode shape and its arrangement on specific patterns can be customized 31 . This versatile electrode shaping can aid in neural structure source identification.…”
Section: Resultsmentioning
confidence: 99%
“…One basic requirement for spike sorting is the spatial relationship between channels. In the presented electrode device, both the electrode size and associated impedance, as well as the electrode shape and its arrangement on specific patterns can be customized 31 . This versatile electrode shaping can aid in neural structure source identification.…”
Section: Discussionmentioning
confidence: 99%
“…One basic requirement for spike sorting is the spatial relationship between channels. In the presented electrode device, both the electrode size and associated impedance, as well as the electrode shape and its arrangement on speci c patterns can be customized 31 . This versatile electrode shaping can aid in neural structure source identi cation.…”
Section: Discussionmentioning
confidence: 99%
“…The peel-and-stick device replaced the use of an invasive and cumbersome needle electrode. Because of the self-adhering and non-invasive design of the electrode array, the array enabled the measurement of electrical signals over a prolonged period 44 . In terms of structural benefit, the flexible sensory array enabled conformal contact with the human skin which will further reduce noise during recording.…”
Section: Discussionmentioning
confidence: 99%