2018
DOI: 10.1016/j.talanta.2017.09.069
|View full text |Cite
|
Sign up to set email alerts
|

Electrochemical strategy for pyrophosphatase detection Based on the peroxidase-like activity of G-quadruplex-Cu2+ DNAzyme

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
9
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 25 publications
(9 citation statements)
references
References 39 publications
0
9
0
Order By: Relevance
“…Besides hemin, it was demonstrated that the human telomeric DNA assembled with Cu 2+ ions can present DNAzyme activity, being able to catalyze the Friedel-Crafts reaction in water with excellent enantioselectivity [ 134 , 135 ]. Based on a Cu 2+ /GQ DNAzyme, an electrochemical method for pyrophosphatase (PPase) activity detection was developed [ 136 ]. In the absence of PPase, Cu 2+ coordinated with pyrophosphate (PPi) to form a Cu 2+ -PPi compound.…”
Section: G-quadruplex Electrochemical Biosensor Applicationsmentioning
confidence: 99%
See 1 more Smart Citation
“…Besides hemin, it was demonstrated that the human telomeric DNA assembled with Cu 2+ ions can present DNAzyme activity, being able to catalyze the Friedel-Crafts reaction in water with excellent enantioselectivity [ 134 , 135 ]. Based on a Cu 2+ /GQ DNAzyme, an electrochemical method for pyrophosphatase (PPase) activity detection was developed [ 136 ]. In the absence of PPase, Cu 2+ coordinated with pyrophosphate (PPi) to form a Cu 2+ -PPi compound.…”
Section: G-quadruplex Electrochemical Biosensor Applicationsmentioning
confidence: 99%
“…Using 3,3′,5,5′-tetramethylbenzidine as a redox mediator, the Cu 2+ /GQ DNAzyme catalyzed the reduction of H 2 O 2 to generate a quantitative chronoamperometric signal. This method was additionally applied to screen the sodium fluoride inhibitor for PPase [ 136 ].…”
Section: G-quadruplex Electrochemical Biosensor Applicationsmentioning
confidence: 99%
“…A variety of analytical methods toward UA detection have thus far been reported, including colorimetry [9], fluorometry [10], high‐performance liquid chromatography [11], electrophoresis [12] and electrochemistry [13–15]. Conventionally, enzyme‐based electrochemical methods take unparalleled advantages due to their specificity [16, 17]; however, most enzymes are unstable under conditions such as acid, alkali, and heat, and their structural changes cause them to lose their catalytic activity [18, 19]. In addition, the content of natural enzymes is shallow, and it is difficult to obtain a large amount by purification, so the price is high, which greatly limits its practical application [20].…”
Section: Introductionmentioning
confidence: 99%
“…So far, several analytical techniques have been developed for PPase detection. Wang et al used a G-quadruplex modified screen-printed electrode for PPase detection [ 4 ]. A two-stage reaction of H 2 O 2 –TMB was carried out upon the release of Cu 2+ from the PPi complex after hydrolysis by PPase.…”
Section: Introductionmentioning
confidence: 99%