“…The results in Figure 8 and Table 1 indicate that the EPI-coated CRS coupon shows a higher E corr value than does the uncoated CRS, which is consistent with the results of earlier studies [15][16][17][18]. Moreover, the EPGN materials showed a higher E corr , R p , and P EF and lower I corr values than does the EPI.…”
Section: Potentiodynamic Measurementssupporting
confidence: 89%
See 2 more Smart Citations
“…The results in Figure 8 and Table 1 indicate that the EPI-coated CRS coupon shows a higher E corr value than does the uncoated CRS, which is consistent with the results of earlier studies [15][16][17][18]. Moreover, the EPGN materials showed a higher E corr , R p , and P EF and lower I corr values than does the EPI.…”
Section: Potentiodynamic Measurementssupporting
confidence: 89%
“…In this study, the polymers were characterized by CV using a three-electrode electrochemical cell. As shown in Figure 7, the electrochemical CV results indicate that the EPGN materials (e.g., EPGN1) in the form of a coating showed a single oxidation peak, which was similar to the case of the EPI [17]. EPGN1 showed an oxidation current (I ox ) of 271.9 µA/cm 2 and a reduction current (I red ) of 376.6 µA/cm 2 ; the latter was smaller than that of the EPI (I ox = 141.3 µA/cm 2 , I red = 236.8 µA/cm 2 ).…”
Section: Electroactivity Of Epi and Epgn Coatingsmentioning
confidence: 53%
See 1 more Smart Citation
“…Furthermore, the electrochemical behaviors of electroactive polyamide with amine-capped aniline pentamer prepared by oxidative coupling polymerization had also been demonstrated by Zhang and co-workers [17][18][19][20][21]. Lately, Yeh et al reported the corrosion protection effect of organo-soluble electroactive polyimide containing amine-capped aniline trimer coated onto cold-rolled steel (CRS) electrode by performing series of electrochemical corrosion measurements in saline condition [22].…”
Section: Introductionmentioning
confidence: 94%
“…The as-prepared mixture was then stirred for an additional 2 h at room temperature under nitrogen. It was subsequently poured onto the supporting substrate to form the electroactive polyimide and then dried under vacuum at 60 • C for 3 h, 100 • C for 1 h, 200 • C for 1 h and 250 • C for 4 h, sequentially, to give EPI material [22].…”
Section: Preparation Of Electroactive Polyimide (Epi) Filmsmentioning