2006
DOI: 10.1016/j.electacta.2006.03.079
|View full text |Cite
|
Sign up to set email alerts
|

Electrochemical study of S–nitrosoglutathione and nitric oxide by carbon fibre NO sensor and cyclic voltammetry – possible way of monitoring of nitric oxide

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
16
0

Year Published

2007
2007
2014
2014

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 36 publications
(16 citation statements)
references
References 85 publications
0
16
0
Order By: Relevance
“…Many techniques, approaches, and procedures have been proposed for investigation of GSH complexes with other molecules [4,12,[14][15][16][17]. Electrochemical methods seem to be very advantageous for the study of GSH [4,18,19].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Many techniques, approaches, and procedures have been proposed for investigation of GSH complexes with other molecules [4,12,[14][15][16][17]. Electrochemical methods seem to be very advantageous for the study of GSH [4,18,19].…”
Section: Introductionmentioning
confidence: 99%
“…Reduced glutathione plays a number of key roles in the control of signal processes, cell division, immune response, programmed cell death, and detoxification of some xenobiotics and heavy metals [1,2]. From a physicochemical point of view, GSH is highly reactive and is often found conjugated to other molecules via its sulfhydryl moiety, including heavy metal ions [3,4].…”
Section: Introductionmentioning
confidence: 99%
“…This is due to a redox activity of GSNO. Indeed, similar reductive peak was recently reported in the case of GSNO on a hanging mercury electrode [18]. But the most remarkable result is that no redox process occurs in the potential range where GSH is expected to be oxidized.…”
mentioning
confidence: 72%
“…This increases the informative capacity of the assay and eliminates interference between species. For example, with scanning voltammetry, the concentrations of all redox species in a sample, including NO, NO 2 − and N x O y or GSH, GSSG and GSNO, can be determined by the distribution and amplitude of anodic current peaks [325,326].…”
Section: Electrochemical Detection (Ecd)-electrochemical Detection (Ementioning
confidence: 99%
“…A variety of amperometric sensors specifically developed for the analysis of NO recently has been reviewed [325,326,328,329]. In combination with CE, the ECD techniques (CEECD) expand the range of accessible analytes without derivatization.…”
Section: Electrochemical Detection (Ecd)-electrochemical Detection (Ementioning
confidence: 99%